Wednesday, August 25, 2010

DtiCorp.com Is Introducing 8 Honeywell W7751 Controllers | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 8 Honeywell W7751 Unitary Controllers for Excel 5000.
The W7751B,D and F are VAV II Controllers in the Excel 10 family product
line. These VAV controllers provide pressure independent or pressure
dependent air flow control and series and parallel (induction) fan
control using single and dual duct applications. VAV systems generally
provide cool air only to the zones. The W7751 controllers provide
additional outputs that control VAV box reheat coils. The heaters can be
staged electric or modulating hot water. Supply and exhaust
pressurization control are provided on a zone basis. W7751H and J Smart
VAV Actuator are factory-integrated VAV Box Controllers with a 90 second
ML6174B Direct-Coupled Actuator in the Excel 10 family product line.


Features:


- Uses Echelon LonWorks protocol.


- W7751B,D,F use Free Topology Transceiver (FTT) networks and are
compliant with VAV device object type number 8010 functional LonMark
profile.

- Energy saving setpoint reset for electrical demand limit control.

- Actuator included with W7751H mounts directly onto VAV box damper
shaft and has up to 35 lb. in. torque, 90 degrees stroke, and 90 sec.

- Timing at 60 Hz.

- High speed 78 kilobit communications network.

- Capable of standalone operation, but uses E-Bus network communications.

- Easy user-access to the network communications jack.

- Uses enhanced microbridge-type airflow sensor with dual integral restrictor design.

- Easy user-access to airflow sensor inputs.


- Provides Proportional Integral Derivative (PID) temperature control.

- Designed for pressure independent Variable Air Volume (VAV) control.

- Floating hot water and three-stage electric or modulating hot water heat.

- Provides nonlinear floating algorithm for velocity control loops.

- Individual zone pressurization for supply and exhaust control.

- Factory configured via EEPROM with critical user parameters default values.

- Motion sensor interface for enhanced energy savings.

- Supports Terminal Regulated Air Volume (TRAV) concept.

- Pressurize and depressurize, night purge, and morning warm-up sequences supported.


- Wall module options for sensor, setpoint and bypass.

- Software selectable limits on remote setpoint adjustments.

- Three integrated 8 bit pipelined microprocessors running at 10 MHz.

- 14 bit A/D converter.

- 32K by 8 ROM/PROM, 512 bytes of EEPROM, and 2048 bytes of static RAM.

- W7751D,F mount to a standard 4 x 4 in. and 5 x 5 in. junction box or snapped to 35 by 7.5mm EN50022 DIN Rail.

- Subbase provides the slotted hole pattern for the R7450 series IRC devices (118×87 mm)


Specifications:


- When the VAV II controller is being balanced, the configuration or balancing tool may indicate stable


airflow and allow balancing before the controller has actually reached
the balancing control setpoint. During this period, if any measurements
are made of the actual airflow volume and entered while the controller
is still ramping to the airflow setpoint, erroneous balancing results
may be recorded.

- All VAV II controllers must be balanced for both minimum and maximum
airflow for highest accuracy. If the controller’s final configuration is
to be a constant volume unit, a minimum airflow balance is

recommended.

- Excel 10 VAV II Controllers must have an air flow pickup table
downloaded to ensure accurate balancing. Configuration tools do not
automatically install the flow pickup table defined for the controller.

- If VAV II Controllers are not balancing, check with the Honeywell
Authorized technician or Honeywell contractor that the flow pickup table
download to each controller has occurred.

- Anytime the controller’s airflow measurement process is to be tested or troubleshooting is attempted, the

airflow must be constant. The VAV II controller should be fixed at some
desired or stable setpoint that is not changed during troubleshooting or
testing.

- Anytime the airflow pickup tubes are disconnected from the controller, the controller should be powered

down. There is no chance of damage to the controller, but if the
controller is exposed to unusually high static pressure (< 5.0 in.
w.c.) when one pickup tube is connected there is a very slight
possibility that the


controllers sensing process will stop operating. Should this condition
be suspected, simply cycle power to the controller. It is not possible
for this condition to occur under normal operation with both airflow
pickup tubes connected to the controller.

- Physical measurement of the flow pickup pressure for the purpose of
testing is best done with an instrument capable of displaying pressure
to 0.01 ±0.005 in. w.c. Though electronic gauges and sensors often offer
the necessary accuracy, their sensitivity can cause problems in field
applications.


Models available:


1. W7751B2010 Excel 10 VAV II controller compatible Printed Wiring Board


2. W7751C1002 Excel 10 series 1000 VAV controller


3. W7751D2016 Excel 10 VAV II controller with two piece construction and an internally wired subbase


4. W7751E1007 Excel 10 series 1000 VAV controller


5. W7751F2011 Excel 10 VAV controller with two piece construction and an externally wired subbase


6. W7751G1003 Excel 10 series 1000 VAV controller



7. W7751H2025 Excel 10 smart VAV controller with a premounted ML6161 Actuator


8. W7751J2004 Excel 10 smart VAV controller with a premounted ML6161 Actuator


About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com

Wednesday, August 18, 2010

10 New Honeywell Excel 5000 Controllers from DtiCorp.com | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 10 New Honeywell Excel 5000. The Excel
500 and 600 Controllers are direct-digital control,
microprocessor-based, programmable controllers that manage building
functions. An Excel 500 can include up to 18 plug-in modules including a
computer module, power supply module, optional modem module, and a
site-specific set of analog and digital input/output modules. The Excel
500 uses a standard computer module. The flexibility of Excel 500/600
easily accommodate expansion. A network can link Excel 5000 system
controllers (Excel 50, 100, 500, and 600), a Q7645A Excel Link, Q7750
Zone Manager, and a Communication System Server on a peer-to-peer
Communication Bus (C-Bus) so they can exchange data. The optional Excel
XI581/2 Operator Terminal provides an operator interface that supports
an interactive question-response dialog for easy access to messages and
controller data. The optional Excel X1584 Portable Operator Terminal
(POT) is a software tool that runs on a portable computer and is used to
install applications programs, implement on-site adjustments, and
access controller information.



Features:


- Bus-Wide MMI provides local viewing/modification of point information of all controllers attached to the Communication Bus.

- Modular design to allow expansion.

- Optional Distributed I/O for flexibility and easy installation.

- Stand-alone or networked operation for flexible use.

- Plug-in modules to use what you need.

- CARE-generated application programs for programming ease.

- Optional user interface for easy on-site changes.

- Battery-backed RAM eliminates reprogramming after power outage.


- Point trending for timely information.


Product Specifications:


- Description: Output Module

- Application: Output Module

- I/O Count: 3 three position relays

- Building Management Interface: ACSELON

- Building Management Interface: EBI

- Building Management Interface: SymmetrE

- Network Communications: C-Bus


- Network Communications: LonWorks Bus

- Commissioning Software: CARE


Models available:


1) XC5010C Excel 500 16-bit CPU module


2) XF522A Analog Output Module


3) XF523A Digital Input Module


4) XF524A Digital Output Module


5) XF525A Three Position Output Module


6) XF526 Analog Input Module



7) XF529 Digital Output Module


8) XH561 Excel 500 or 600 Universal Input/Output Module Housing


9) XH562H Universal Input/Output Blank Housing Cover


10) XP502 Power Supply Module


About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com


Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com



ListFree.org: Embedded data.



ListFree.org (Press Release) - Wednesday, August 18th, 2010 -







Bookmark and Share


Subscribe


 



Tuesday, August 10, 2010

DtiCorp.com Is Introducing 8 Honeywell C7061 Flame Sensors | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com
(http://www.DtiCorp.com) is introducing 8 Brand New Honeywell C7061
Flame Sensors. Dynamic self-checking flame detector used with R7861
Dynamic Self-check Amplifiers for sensing the ultraviolet radiation
generated by the combustion of gas, oil, or other fuels. The C7061A is a
dynamic self-checking flame detector for

sensing the ultraviolet radiation generated by the combustion of gas,
oil, or other fuels. This flame detector is available in two versions:
model C7061A for use in Standard applications, and model C7061F for use
in installations requiring explosion-proof packaging. The flame detector
is designed for use with either, R7061 Dynamic Self-Check Ultraviolet
amplifier and R4348 Flame Switch or R7861A Dynamic Self-Check
Ultraviolet amplifier and 7800 SERIES Burner Programmers. These
configurations provide a closed-loop, self-checking circuit which
insures the integrity of both amplifier and flame detector. Improper
response simulated flame loss results in a safety shutdown and/or alarm.


Features:


- Oscillating shutter interrupts ultraviolet radiation reaching the UV sensor to provide the UV sensor tube checking function.

- Can be mounted horizontally, vertically or at any angle in between.

- The detector requires faceplate alignment and has integral locating
reference points to assure proper operation of the shutter mechanism.

- Field replaceable ultraviolet sensing tube and quartz viewing window.


- Models with threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- C7061A1038 or A1046 5 pin Brad Harrison type (formally 41307N) mating connector not supplied nor available through Honeywell.

- Two detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.

- Protective heat block built into mounting flange.

- Minus 40 F (-40 C) rated ultraviolet sensing tube is supplied.

- C7061E meets NEMA 4 standards with viewing window rated to 20 psi.

- C7061F has an explosion-proof housing for use in hazardous atmospheres with a viewing window rated to 100 psi.


Specifications:


- Models


C7061A: Self checking UV flame detector in standard housing.

C7061F: Self checking UV flame detector in explosion proof housing.
Designed for use with either R7061 Dynamic Self-Check Ultraviolet
amplifier and R4348 Flame Switch or with R7861A Dynamic Self-Check
Ultraviolet amplifier and 7800 SERIES Burner Programmers


- Ambient Operating temperature ratings

C7061A: -40°C to +70°C (-40°F to +160°F)“(derate ambient 1°F for every 13°F of aspirator temperature over 160°F).

C7061F: -20°C to +70°C (-22°F to +160°F)


- Storage temperature ratings:

Minus 51°C to +85°C (-60°F to +185°F)


- Voltage and Frequency:

C7061A1004 120 VAC, 50/60 Hz


C7061A1020 115/230 VAC, 50/60 Hz

C7061F1003 115/230 VAC, 50/60 Hz

The System operates correctly at a nominal voltage (-15%, +10%), 50/60 Hz.


- Flame Signal:

Measured at the flame current meter jack.

C7061 Detector: 1.4 to 5.5 micro amps (nominal).

R7061A Amplifier: 2.5 to 5.5 micro amps (nominal).

R7861A Amplifier: 1.25 to 5.0 Volts (On keyboard display module).


- Flame Signal amplifier:


R7061A Dynamic Self-Check Ultraviolet amplifier

R7861A Dynamic Self-Check Ultraviolet amplifier


- Interchangeability:

Models C7061A and C7061F are not interchangeable with other flame detector models.


- Shutter frequency:

0.2 Hz, nominal (when used in combination with 7800 SERIE).

Interrupts the line-of-sight of the detector about 12 times per minute
to provide self-checking. Any malfunction in the flame detection system
results in a safety shutdown. 1Hz nominal when used with R4348 in
combination with R7061 amplifier.


- Pressure rating of quarz viewing window:

C7061A: 138 kPa (20 psi) maximum.


C7061F: 690 kPa (100 psi) maximum


- Enclosure

C7061A: Meets IP66 enclosure requirements (indoor, outdoor protection;
rain-tight, dust-tight, hosedirected water). Optional water jacket
available.

C7061F: IP65 according to DIN 40050


- Weight

C7061A: 3.3 kg (7.3 Ib)

C7061F: 6.3 kg (13.9 Ib)


- Mounting and orientation

C7061A : Mounting flange with 3/4 inch NPT internal threads for attaching to sight pipe.


C7061F: Mounting flange with 1 inch NPT internal threads for attaching to sight pipe.


- Wiring Connections

C7061A1004: NEC Class 1 color coded leadwire.

Length: 8 ft (2.4m).

C7061A1020: Terminal block.

Threaded leadwire opening in faceplate:

1/2-14 NPSM internal threads for attaching conduit.

One brass cable gland standard with housing.


- Serviceability:


Field replaceable viewing window and ultraviolet sensing tube, coil and shutter assembly.


- Maximum cable length:

300 meter between sensor and amplifier


- Approvals:

Underwriters Laboratories Inc. Listed.

Canadian Standards Association Certified: Master File LR95329-1.

Factory Mutual Approved: 14740.01.

lndustrial Risk Insurers Acceptable.


Models available:



1. C7061A1004, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


2. C7061A1012, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


3. C7061A1020, 120 or 230 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


4. C7061A1038, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


5. C7061A1046, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


6. C7061A1053, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


7. C7061F1003, 120/230 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


8. C7061F2001, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than
35,000 HVAC products, including industrial, commercial and residential
parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy,
Grundfos, Armstrong and more. Our online catalog is easy to navigate and
search, and all products have a picture and a description. If a
customer has any questions about a product, they can call 800-757-5999
and speak with one of our product experts. Our mission is to offer the
best prices anywhere to our customers.



Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com

Wednesday, August 4, 2010

DtiCorp.com is introducing 5 Honeywell VS820 Millivolt Gas Valves

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 5 Honeywell VS820 Millivolt Gas Valves. These gas controls combine a Lite-Rite manual gas cock, safety shutoff Pilotstat assembly, millivoltage automatic valve operator, and optional gas pressure regulator. They require the use of a 750 mv Powerpile generator (thermopile). The generator, heated by the pilot burner flame, provides the electrical energy to operate the combination gas control. A millivoltage thermostat with suitable accessory controls completes the automatic control system for the heating appliance.


Models equipped with the standard pressure regulator are identified by the suffix letter “A“ (WS820A). Models without pressure regulator carry the suffix letter “B” (VS820B). Suffix letter “C” (VS82OC) identifies models having step opening type regulators. Pressure regulators and operator are standardized and interchangeable on all models in the two capacity ranges – 225 and 335 cubic feet per hour.


Features:



- Include pilot flow adjustment screw.


- Easy to install, adjust and service; all adjustments and connections are accessible from top of control.


- Add separate energy cutoff (ECO) where codes call for dual safety shutoff.


- Complete safety shutoff on pilot flame failure.


- LITE-RITE (OFF-PILOT-ON) lighting sequence.


- ECO connector for V800 models, Part No. 392451-1.


Specifications:


1. These controls can be mounted 0-90 degrees, in any direction, from the upright position of the gas

cock knob.


2. Install the control so that gas supply is connected to the end provided with projecting boss for wrench application.

3. After Powerpile generator is installed, route generator lead to Powerpile operator and connect to

Powerpile terminals labeled PP. Make certain jumper lead from Powerpile operator to safety shutoff

Pilotstat power unit is connected and tightened l/4 turn beyond finger tight.

4. The pilot flame should envelop 3/8 to l/2 inch of the tip of the thermocouple. Remove pilot adjustment cover screw. Turn inner adjustment screw clockwise to decrease or counterclockwise to increase pilot flame.

5. Check burner performance at step pressure, observing burner ignition and flame characteristics.

Burner should ignite properly and without flashback to orifice, and all ports should remain lit.

6. Do not exceed input rating stamped on nameplate of appliance, or manufacturer’s recommended burner orifice pressure for size orifice(s) used. Make certain primary air supply to main burner is properly adjusted for complete combustion. Follow instructions of appliance manufacturer if provided.

7. Make certain there is no gas flow through the meter other than to the appliance being checked.


Other appliances must remain off, and the pilot extinguished (or their consumption deducted from

the meter reading).

8. Put the system into operation and observe through complete cycle to be sure all controls function

properly. Make certain the Pilotstat unit shuts off gas flow to main burner within 2-l/2 minutes after pilot

flame is extinguished.

9. Approvals, Underwriters Laboratories Inc: UL Component Recognized

10. Approvals, American Gas Association: AGA Design Certified: File no. L2025003

11. Approvals, Canadian Gas Association: CGA Design Certified: File no. L2025003


Models available:



1. VS820A1047 1/2 in. NPT x 3/4 in. NPT PowerPile Millivolt Combination Gas Valve with 3.5 in. wc adjustable pressure regulator setting


2. VS820A1054 3/4 in. NPT x 3/4 in. NPT PowerPile Millivolt Combination Gas Valve with 3.5 in. wc adjustable pressure regulator setting


3. VS820A1088 3/4 in. NPT x 3/4 in. NPT PowerPile Millivolt Combination Gas Valve with 3.5 in. wc adjustable pressure regulator setting


4. VS820A1336 3/4 in. NPT x 3/4 in. NPT PowerPile Millivolt Combination Gas Valve with 10.0 in. wc adjustable pressure regulator setting


5. VS820C1100 3/4 in. NPT x 3/4 in. NPT PowerPile Millivolt Combination Gas Valve with Step: 0.9 in. wc non-adjustable; Full rate: 3.5 in. wc, 3-5″ adjustable pressure regulator setting


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.


Julian Arhire


Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com


ListFree.org: Embedded data.




Bookmark and Share



Subscribe