Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 6 brand new Honeywell R8184 Protectorelay Oil Burner Controls. The Honeywell Protectorelay Oil Burner Controls operate the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit.



Features:



- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.

- Solid state flame sensing circuit.

- LED on terminal strip indicates system lockout.

- Remote lockout indication available on some models.

- Enclosed safety switch with external reset button.

- Manual trip lever opens safety switch for system maintenance.

- Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.

- C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required.



Specifications:



- Solid-state electronic circuitry provides low power consumption and high reliability.

- Solid-state models directly replace previous models with vacuum electron tube circuitry.

- Detectors can be mounted horizontally, vertically or at any angle. The self-checking C7012E,F models
require faceplate alignment and have integral locating reference points to assure proper shutter mechanism operation.

- Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.

- Threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame
sighting applications.

- A swivel mount is available to facilitate flame sighting.

- Models are available with a -40°F (-40°C) rating.

- Designed for use with Honeywell Flame Safeguard Controls using Honeywell Rectification (R7247A,
R7289A, R7847A1082) and Ampli-Check Rectification (R7247B, R7847B1072) Flame Signal Amplifiers.



- C7012G models available to meet BGC (British) and DIN (German) requirements.

- Incorporate UV sensor tube checking feature; used with Honeywell Dynamic Self-Check (R7247C, R7847C) Flame Signal Amplifiers.



Models available:




1. R8184G4009 Protectorelay Oil Burner Control with 45 seconds lock out timing


2. R8184G4025 Protectorelay Oil Burner Control with 45 seconds lock out timing


3. R8184G4066 Protectorelay Oil Burner Control with 15 seconds lock out timing


4. R8184G4074 Protectorelay Oil Burner Control with 30 seconds lock out timing


5. R8184G4082 Protectorelay Oil Burner Control with 45 seconds lock out timing


6. R8184M1051 Protectorelay Oil Burner Control with 45 seconds lock out timing




About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.




Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com

Monday, September 20, 2010

27 New Honeywell C7005 and Q179 Gas Pilot Burner Assemblies from DtiCorp.com

Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)

is introducing 27 New Honeywell C7005 and Q179 Gas Pilot Burner
Assemblies. Honeywell Gas Pilot Burner Assemblies include a flame rod to
prove the pilot flame. The assemblies are used with a suitable flame
safeguard control on industrial or commercial gas burners or oil burners
with gas pilots.


Features:


- Used with Honeywell controls using the flame rectification principle.

- C7005A is for continuous pilot applications.

- It includes an insulated flame rod, properly positioned relative to
the flame retention type nozzle. C7005B is similar to C7005A, but
includes an ignition electrode suitable for automatic, electric-spark
ignition, gas pilot applications.

- Individually mounted flame rod and ignition electrode in ceramic
insulators allow the head assembly to fit inside a 3-inch pipe.

- Stainless steel fins on the flame retention type pilot head provide
the correct ratio of flame rod area to ground area for maximum flame
signal, and are beneficial in stabilizing the pilot flame.

- Pilot flame retention nozzle and mixing tube are threaded internally,
1/2-14 NPT and 3/8-18 NPT, respectively, and can be assembled with
standard pipe fittings.

- Pilot can be installed in vertical, horizontal, or inclined position.


- Rajah connectors facilitate electrical connections.


Product Specifications:


- Models:

C7005A Gas Pilot and Flame Rod Assembly for continuous pilot applications; includes flame rod only.

C7005B Gas Pilot and Flame Rod Assembly for automatic pilot applications; includes flame rod and ignition electrode.


- Pilot Head:

Flame retention type with stainless steel bomb type fins. Threaded onto
1/2 x 6 inch (152 mm) pipe nipple with 1/2-14 NPT external threads.


- Type of Gas:

Models available for use with natural and propane gases.



- Insulator Brackets:

Adjustable to change location of flame rod or ignition electrode; lock securely using setscrew.


- Mixing Tube:

Inspirating (Venturi type) with primary air adjustment. Approximately
4-9/16 inches (116 mm) long, 1-3/4 inches (44.5 mm) diameter. Inlet
tapping 1/4-18 NPT; outlet tapping 3/8-18 NPT.


- Mounting:

Vertical, horizontal, or inclined.


- Dimensions:

Overall Height 13-1/2 inches (343 mm); width can be adjusted to pass through a 3-inch pipe.

Pilot Head Length 4-7/16 inches (113 mm), diameter 1-5/8 inches (41.3
mm). Spark Gap (C7005B only) 1/8 to 3/16 inch (3.2 to 4.8 mm).



- The C7005B Gas Pilot and Flame Rod Assembly includes an ignition
electrode and a flame rod. The operation of these two electrodes in a
simple electrically-operated, gas pilot installation.


- At the beginning of the starting cycle, a high voltage from the
secondary winding of the ignition transformer is applied to the ignition
electrode. A spark jumps across the outlet of the pilot burner. The
pilot gas valve is either automatically or manually opened, and the
spark ignites the gas.


- When the ignition transformer is energized, ac voltage is applied
to the flame rod through a flame safeguard control. When the pilot flame
appears, this ac voltage is changed to dc voltage through a rectifying
action. This dc voltage then operates a relay, opening the valve to the
main burner (or permitting it to be manually opened). In the event of
flame failure, flame rectification stops, the gas valves are
deenergized, the valves close, and the system shuts down.


- Approvals:

Underwriters Laboratories Inc. Listed: File No. MP268.

Canadian Standards Association Certified: C7005 only

Master file LR-95329-1.

Industrial Risk Insurers acceptable.


Models available:



1. C7005A1037 Flame Rectifier Pilot with a 0.052 in. dia. Orifice


2. C7005B1035 Flame Rectifier Pilot with a 0.052 in. dia. Orifice


3. C7005B1050 Flame Rectifier Pilot with a 0.028 in. dia. Orifice


4. Q179A1001 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


5. Q179A1035 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree right hand port and tip style


6. Q179A1050 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and T tip style


7. Q179A1076 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and 45 degree Y port and tip style


8. Q179A1092 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and 45 degree T port and tip style


9. Q179A1118 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree left hand port and tip style



10. Q179A1126 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


11. Q179A1183 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


12. Q179B1042 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and T tip style


13. Q179B1109 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree left hand port and tip style


14. Q179B1117 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree I port and tip style


15. Q179C1009 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


16. Q179C1025 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Rear Target Mount and L tip style


17. Q179C1033 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Left Side Target Mount and D tip style


18. Q179C1041 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Right Side Target Mount and D tip style



19. Q179C1058 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Left Side Target Mount and L tip style


20. Q179C1066 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Right Side Target Mount and K tip style


21. Q179C1090 Miniature Flame Rectifier Pilot with 0.016 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


22. Q179C1108 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


23. Q179D1008 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


24. Q179D1016 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Left Side Target Mount and D tip style


25. Q179D1024 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Right Side Target Mount and D tip style


26. Q179D1057 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Left Side Target Mount and L tip style


27. Q179D1925 Miniature Flame Rectifier Pilot with 0.016 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style



About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com





Friday, September 10, 2010

DtiCorp.com Is Introducing 19 Honeywell C7012 Flame Detectors

Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 19 Honeywell C7012 Solid State Purple Peeper Ultraviolet
Flame Detectors. Solid state electronic flame detectors for use with
Honeywell Flame Safeguard controls and amplifiers. Sense ultraviolet
radiation produced by combustion of gas, oil, coal or other fuels.


Features:


- Mount horizontally, vertically or at any angle in between.

- Provide quick electrical hookup with threaded conduit fitting and color-coded leadwires.

- Reduced nuisance shutdowns by wiring two in parallel.


- C7012E1278 5 pin Brad Harrison type (formally 41307N) mating connector not supplied nor available through Honeywell.

- C7012A,E meets NEMA 4 standards with viewing window rated to 20 psi.

- C7012C,F has an explosion-proof housing for use in hazardous atmospheres with a viewing window rated to 100 psi.


Specifications:


- Solid-state electronic circuitry provides low power consumption and high reliability.

- Solid-state models directly replace previous models with vacuum electron tube circuitry.

- Detectors can be mounted horizontally, vertically or at any angle. The self-checking C7012E,F models

require faceplate alignment and have integral locating reference points to assure proper shutter mechanism operation.

- Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.


- Threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame

sighting applications.

- A swivel mount is available to facilitate flame sighting.

- Models are available with a -40°F (-40°C) rating.

- Designed for use with Honeywell Flame Safeguard Controls using Honeywell Rectification (R7247A,

R7289A, R7847A1082) and Ampli-Check Rectification (R7247B, R7847B1072) Flame Signal Amplifiers.

- C7012G models available to meet BGC (British) and DIN (German) requirements.

- Incorporate UV sensor tube checking feature; used with Honeywell Dynamic Self-Check (R7247C, R7847C) Flame Signal Amplifiers.



Models available:


1. C7012A1145 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


2. C7012A1152 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


3. C7012A1160 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


4. C7012A1186 208 Vac Flame Sensor, Ultraviolet, Purple Peeper


5. C7012A1194 240 Vac Flame Sensor, Ultraviolet, Purple Peeper


6. C7012C1042 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Explosion Proof


7. C7012E1104 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


8. C7012E1112 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking



9. C7012E1120 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


10. C7012E1146 208 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


11. C7012E1153 240 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


12. C7012E1161 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


13. C7012E1187 220 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


14. C7012E1195 110 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


15. C7012E1203 240 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


16. C7012E1245 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


17. C7012E1278 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking



18. C7012F1052 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


19. C7012G1019 220 Vac Flame Sensor, Ultraviolet, Purple Peeper


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products,
including industrial, commercial and residential parts and equipment
from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong
and more. Our online catalog is easy to navigate and search, and all
products have a picture and a description. If a customer has any
questions about a product, they can call 800-757-5999 and speak with one
of our product experts. Our mission is to offer the best prices
anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767


Web: http://www.DtiCorp.com


Friday, September 3, 2010

9 New Honeywell R7847 Flame Amplifiers from DtiCorp.com | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)

is introducing 9 New Honeywell R7847 Flame Amplifiers – Honeywell
solid state plug-in amplifiers that respond to flame detector inputs to
indicate the presence of flame when used with 7800 SERIES relay modules.
The R7847A,B Rectification Flame Amplifiers are solid state plug-in
amplifiers that respond to a rectified signal from a rectification type
flame detector to indicate the presence of flame when used with 7800
SERIES Relay Modules.


Features:


- Flame failure response time of 0.8 or 3.0 seconds.

- Flame signal strength ranges from 0.0 to 5.0 Vdc.

- Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation.

- Flame signal test jacks to measure amplifier flame signal voltage.

- Color-coded labels identify flame detection type. Dynamic Self-Check
Amplifier test the detectors and all electronic components in the flame
detection system 7800 SERIES relay module locks out on safety shutdown
with flame detection system failure.

- Compatible with existing Honeywell flame detectors (sold separately).


Product Specifications:



- Flame failure response time of 0.8 or 1 second; or 2.0 or 3.0 seconds, depending on the amplifier and relay module selected.

- Plug-in to 7800 SERIES and R7140 Relay Module through printed circuit board edge connector keyed

for proper orientation.

- Flame signal test jacks measure amplifier flame signal voltage.

- 0.0 to 5.0 Vdc Flame signal strength reading range.

- Color coded label identifies flame detection type:

* Green—rectification. Red—infrared.

* Purple—ultraviolet. Blue—pulsed rectification.

* White—optical.


- R7847B, R7848B, R7849B Dynamic Ampli-Check circuitry tests all flame
amplifier components 12 times per minute. The 7800 SERIES and R7140
Relay Module locks out on safety shutdown with amplifier failure.

- R7824C, Series 2 or greater and R7847C Series 4 or greater, pulse the shutter when signal of 1.5 Vac

is sensed. Display readings of 0.7 to 2.4 Vdc are common.

- R7824C, R7847C Dynamic Self-Check Rectification Amplifier, R7851C
Dynamic Self-Check Optical Flame Amplifier, R7861 Self-Check Ultraviolet
Flame Amplifier and R7886A Dynamic Self-Check Ultraviolet Amplifier
test the detectors and all electronic components in the flame detection
system 12 times per minute. The 7800 SERIES and R7140 Relay Module locks
out on safety shutdown with flame detection system failure.


Models available:


1) R7847A1025 Flame Amplifier, Rectification, FFRT: 0.8 sec or 1.0 sec, for 7800 Series Relay Modules


2) R7847A1033 Flame Amplifier, Rectification, FFRT: 2.0 sec or 3.0 sec, for 7800 Series Relay Modules


3) R7847A1074 Flame Amplifier, Rectification, FFRT: 0.8 sec or 1.0 sec, for 7800 Series & R7140 Relay Modules



4) R7847A1082 Flame Amplifier, Rectification, FFRT: 2.0 sec or 3.0 sec, for 7800 Series or R7140 Relay Modules


5) R7847B1023 Flame Amplifier, Rectification Ampli-Check, FFRT: 0.8 sec or 1.0 sec, for 7800 Series Relay Modules


6) R7847B1031 Flame Amplifier, Rectification Ampli-Check, FFRT: 2.0 sec or 3.0 sec, for 7800 Series Relay Modules


7) R7847B1064 Flame Amplifier, Rectification Ampli-Check, FFRT: 0.8 sec or 1.0 sec, for 7800 Series or R7140 Relay Modules


8) R7847B1072 Flame Amplifier, Rectification Ampli-Check, FFRT: 2.0 sec or 3.0 sec, for 7800 Series or R7140 Relay Modules


9) R7847C1005 Flame Amplifier, Dynamic Self Check for C7012E,F, for 7800 Series Relay Modules





About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products,
including industrial, commercial and residential parts and equipment
from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong
and more. Our online catalog is easy to navigate and search, and all
products have a picture and a description. If a customer has any
questions about a product, they can call 800-757-5999 and speak with one
of our product experts. Our mission is to offer the best prices
anywhere to our customers.



Julian Arhire

Manager DtiCorp.com

Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com



ListFree.org: Embedded data.




ListFree.org (Press Release) - Friday, September 3rd, 2010 -






Bookmark and Share



Subscribe