Wednesday, September 25, 2013

HONEYWELL W7460A1008 Economizer Logic Module from DtiCorp.com

HONEYWELL W7460A1008 Economizer Logic Module from DtiCorp.com

HONEYWELL DH65A1007 Whole-House Dehumidifier from DtiCorp.com

HONEYWELL DH65A1007 Whole-House Dehumidifier from DtiCorp.com

HONEYWELL T631A1030 Thermostat from DtiCorp.com

HONEYWELL T631A1030 Thermostat from DtiCorp.com

HONEYWELL FC40R1102 Return Grill Media Air Filter from DtiCorp.com

HONEYWELL FC40R1102 Return Grill Media Air Filter from DtiCorp.com

HONEYWELL T775M2048 Electronic Temperature Controller from DtiCorp.com

HONEYWELL T775M2048 Electronic Temperature Controller from DtiCorp.com

HONEYWELL THM5421C1008 VisionPRO IAQ Interface Module from DtiCorp.com

HONEYWELL THM5421C1008 VisionPRO IAQ Interface Module from DtiCorp.com

HONEYWELL VCZMS6100 VC valve from DtiCorp.com

HONEYWELL VCZMS6100 VC valve from DtiCorp.com

HONEYWELL RP7517B1016 Electronic Pneumatic Transducer from DtiCorp.com

HONEYWELL RP7517B1016 Electronic Pneumatic Transducer from DtiCorp.com

Tuesday, September 24, 2013

HONEYWELL T7770F1047 non-linear Temperature Wall Module from DtiCorp.com

HONEYWELL T7770F1047 non-linear Temperature Wall Module from DtiCorp.com

HONEYWELL LP920A1021 Pneumatic Temperature Controller from DtiCorp.com

HONEYWELL LP920A1021 Pneumatic Temperature Controller from DtiCorp.com

HONEYWELL V4046B1049 120 Vac Magnetic Valve from DtiCorp.com

HONEYWELL V4046B1049 120 Vac Magnetic Valve from DtiCorp.com

HONEYWELL C7035A1023 Flame Sensor from DtiCorp.com

HONEYWELL C7035A1023 Flame Sensor from DtiCorp.com

HONEYWELL VR8200H1251 24 Vac Dual Standing Pilot Gas Valve from DtiCorp.com

HONEYWELL VR8200H1251 24 Vac Dual Standing Pilot Gas Valve from DtiCorp.com

HONEYWELL 32006028-001 HEPA Filter from DtiCorp.com

HONEYWELL 32006028-001 HEPA Filter from DtiCorp.com

HONEYWELL C554A1463 Cadmium-Sulfide Flame Detector from DtiCorp.com

HONEYWELL C554A1463 Cadmium-Sulfide Flame Detector from DtiCorp.com

HONEYWELL T7080A1019 Electronic Dual Setpoint Thermostat from DtiCorp.com

HONEYWELL T7080A1019 Electronic Dual Setpoint Thermostat from DtiCorp.com

Monday, September 23, 2013

DtiCorp.com is Introducing the New Honeywell V4943A1029 Diaphragm Gas Valve

Fort Lauderdale, FL - Popular online HVAC retailer DtiCorp.com (http://www.DtiCorp.com) is introducing the brand new Honeywell V4943A1029 Diaphragm Gas Valve. V4943A/8943A are on/off diaphragm gas valves. V4943/8943B, C, N are Single-stage Pressure Regulating Valve; V4944/8944B,C, L, N are Two-stage Pressure Regulating Gas Valve. These valves are used on boilers, unit heaters, duct furnaces, makeup air and rooftop heaters.
Features:
- Designed for replacement for V4843/V8843;V4844/V8844 Gas Valves.
- Suitable for use on atmospheric boilers, commercial water heaters, and rooftop heaters.
- V8943/V4943A models are solenoid-operated diaphragm valves for on/off flow control of fuel gases.
- V4943/V8943B,C,N and V4944/V8944B,C,L,N models are solenoid-operated diaphragm valves that combine the functions of safety shutoff and pressure regulation in a single unit.
- V4943/V8943B,N and V4944/V8944B,N are for use with natural gas.
- V4943/V8943C and V4944/V8944C,L are for use with LP gas.
- Valve body of die-cast aluminum with a straight-through pattern.
- V4943 are used with line voltage, on/off controllers; V8944 are used with 24 Vac thermostats or controllers.
- V4944 are used with line voltage, dual-stage controllers; V8944 are used with 24 Vac dual-stage thermostats or controllers.
- Valve closes on power failure; recommended for final shutoff service.

About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.


More information about Honeywell V4943A1029:


Tags: Honeywell V4943A1029, Diaphragm Gas Valve, solenoid-operated diaphragm valves

Sunday, September 22, 2013

HONEYWELL M7284Q1009 120V Non-Spring Return Foot Mounted Actuator from DtiCorp.com

HONEYWELL M7284Q1009 120V Non-Spring Return Foot Mounted Actuator from DtiCorp.com

Honeywell TH9421C1004 VisionPRO IAQ Programmable Thermostat from DtiCorp.com

Honeywell TH9421C1004 VisionPRO IAQ Programmable Thermostat from DtiCorp.com

HONEYWELL P7640B1032 Differential Pressure Transmitter from DtiCorp.com

HONEYWELL P7640B1032 Differential Pressure Transmitter from DtiCorp.com

HONEYWELL ST7800A1054, 60 SECONDS TIMER from DtiCorp.com

HONEYWELL ST7800A1054, 60 SECONDS TIMER from DtiCorp.com

HONEYWELL F76S1031 1 1/4 inch Water filter from DtiCorp.com

HONEYWELL F76S1031 1 1/4 inch Water filter from DtiCorp.com

HONEYWELL MS4120A1001 Two-position, SPST Actuator from DtiCorp.com

HONEYWELL MS4120A1001 Two-position, SPST Actuator from DtiCorp.com

HONEYWELL FC37A1171 Electronic Air Cleaner Cell from DtiCorp.com

HONEYWELL FC37A1171 Electronic Air Cleaner Cell from DtiCorp.com

HONEYWELL XL100CU Freely Programmable DDC controller from DtiCorp.com

HONEYWELL XL100CU Freely Programmable DDC controller from DtiCorp.com

HONEYWELL T100F1395 Thermostatic Radiator Actuator from DtiCorp.com

HONEYWELL T100F1395 Thermostatic Radiator Actuator from DtiCorp.com

HONEYWELL Q270A1024 Wiring Mounting Base from DtiCorp.com

HONEYWELL Q270A1024 Wiring Mounting Base from DtiCorp.com

HONEYWELL S963B1128 Manual Potentiometer from DtiCorp.com

HONEYWELL S963B1128 Manual Potentiometer from DtiCorp.com

HONEYWELL RA890F1288 120 Vac Protectorelay from DtiCorp.com

HONEYWELL RA890F1288 120 Vac Protectorelay from DtiCorp.com

HONEYWELL L4006A1967 High or Low limit Aquastat Controller from DtiCorp.com

HONEYWELL L4006A1967 High or Low limit Aquastat Controller from DtiCorp.com

HONEYWELL M847A1080 Foot Mounted Actuator from DtiCorp.com

HONEYWELL M847A1080 Foot Mounted Actuator from DtiCorp.com

HONEYWELL R8184G4009 Protectorelay Oil Burner Control from DtiCorp.com

HONEYWELL R8184G4009 Protectorelay Oil Burner Control from DtiCorp.com

HONEYWELL T7351F2010 Programmable Commercial Thermostat from DtiCorp.com

HONEYWELL T7351F2010 Programmable Commercial Thermostat from DtiCorp.com

HONEYWELL TB6575A1000 3-Speed Fan Coil Thermostat from DtiCorp.com

HONEYWELL TB6575A1000 3-Speed Fan Coil Thermostat from DtiCorp.com

HONEYWELL T100B1035 Thermostatic Radiator Actuator from DtiCorp.com

HONEYWELL T100B1035 Thermostatic Radiator Actuator from DtiCorp.com

HONEYWELL P658B1012 Panel Mounted Pneumatic / Electric Switch from DtiCorp.com

HONEYWELL P658B1012 Panel Mounted Pneumatic / Electric Switch from DtiCorp.com

HONEYWELL AQ2514B4 Aquatrol Boiler Reset Control Panel from DtiCorp.com

HONEYWELL AQ2514B4 Aquatrol Boiler Reset Control Panel from DtiCorp.com

HONEYWELL ML4115A1009 Fast-Acting, Two-Position Actuator from DtiCorp.com

HONEYWELL ML4115A1009 Fast-Acting, Two-Position Actuator from DtiCorp.com

HONEYWELL EA79A1004 Industrial Automatic Air Vent from DtiCorp.com

HONEYWELL EA79A1004 Industrial Automatic Air Vent from DtiCorp.com

Saturday, September 21, 2013

DtiCorp.com is Introducing the New Honeywell LG1093AC01 Turbine Flame Sensor

Fort Lauderdale, FL – Popular online HVAC retailer DtiCorp.com (http://www.DtiCorp.com) is introducing the brand new Honeywell LG1093AC01 Turbine Flame Sensor – GE Part Number 314A5030P01. Industrial power generation gas turbine installations demand the superior protection provided by the Honeywell UV Flame Monitoring System. The Honeywell flame monitor system detects the ultraviolet radiation emitted by a hydrocarbon flame and produces an output signal to indicate a flame or no-flame condition. This system has delivered proven performance on General Electric (and GE licensee) gas turbines for more than 35 years. Land-based and off-shore applications include power generation, pumping stations, shipboard power generation among other industrial uses. A variety of sensors types, amplifier types and sensor cable lengths are available. Flame monitoring of a burner has comprised the use of thermocouples, expansion tubes, and radiation sensors. Due to the extremely high flame temperatures in process boilers, monitoring of boiler flames in large furnaces has been done mainly with remotely located radiation sensors or sonic microphone pickups, which detect the frequency of the flame.
Although the radiation sensor circumvents the problem of placing a sensor in the region of high flame temperature, it has shortcomings such as the inability to differentiate between flame radiation and radiation from the heated boiler or furnace wall regions. Thus, the flame may be extinguished and the flame detector will fail to respond. The fuel supply to the burners will continue to be discharged onto the hot furnace walls. This time lag between loss of flame and shut down of the fuel supply can cause an explosion.
There are specialized radiation sensors which sense ultraviolet radiation and others which generate signals corresponding to the amplitude of the high frequency flicker of the flame monitored. The sensors can distinguish between flame radiation and background radiation since both ultraviolet and flickering radiation find a source of excitation exclusively in the flame. The use of a flickering type radiation sensor produces an output signal that is continuously fluctuating. The fluctuation may be hard to distinguish, and the problem becomes one of accurate detection of this fluctuation.
Sensors are positioned to converge and the radiation magnitude received by the individual sensors is similar. A circuit means subtracts the output signals of the individual sensors of the pair, the steady and slowly varying components of flame radiation from the flame are effectively canceled leaving the rapidly varying difference signal for flame detection. The high frequency flame flickering is due to random pulses or burst of radiation from very localized sources in the flame, and there will always be a residual, varying component from the dual sensor system as long as the flame is present.
Features:
- High sensitivity with fast response time (0.1 sec typical)
- Amplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.
- Operating distances up to 1000 feet, sensor to amplifier.
- Available with Factory Mutual approval for explosive atmospheres.
- Available with European Directive CE mark for EMC 89/336/EEC, LVD 73/23/EEC and ATEX Explosive Atmosphere 94/9/EC.
- Qualified component on General Electric turbines.
Specifications:
- Geiger Mueller-type sensor phototube. Detects ultra-violet band and 1800 – 2600 angstroms. “Solar blind” and tolerant to black body radiation.
- Two-year shelf-line, 10,000 hours MTBF with over one billion operating hours.
- Mounting Interface: 3/4 inch internal NPT.
- Control Panel Connection: Teflon shielded cable with one inch external conduit thread.
- Operating Temperature: -40°F to +350°F.
- Window Pressure Rating: 150 psig at 400°F.
- Special Certifications:
- Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D
- CE Mark: EMC Directive 89/336/EEC, ATEX Directive 94/9/EC, II 2G, EEx d IIA T3 or EEx d IIC T3 Models
AA34/35/36/44/45/46
- Cable Lengths:
- AA24/AA34: 16ft (4.9m)
- AA25/AA35: 42ft (12.8m)
- AA26/AA36: 61ft (18.6)

About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.

More information about Honeywell LG1093AC01:
http://dticorp.com/catalog/honeywell-lg1093ac01-turbine-flame-sensor-p-5520.html

Friday, September 20, 2013

DtiCorp.com is Introducing the New Honeywell IRIS S550B as Replacement for S550

Fort Lauderdale, FL – Popular online HVAC retailer DtiCorp.com (http://www.DtiCorp.com) is introducing the brand new Honeywell IRIS S550B Viewing Head For Flame Monitor as replacement for Honeywell S550. The IRIS Model S550B is a state-of-the-art Flame Monitor viewing head utilizing two types of detectors, an IR (infrared) solid state and UV (ultraviolet) tube. The S550B works with the latest version of the P520/P522 signal processors. Like other viewing heads in the S500 family of viewing heads, the S550B produces output pulse rates proportional to the flame signal strength; the pulse rates are displayed at the front panel of the signal processors. But, unlike the other members of the S5xx family of viewing heads, certain parameters in the S550B viewing head (UV gain, IR gain and filter selection) can be selected or adjusted remotely from the front panel of the P520/P522 signal processors.
Once adjusted, the new parameters are stored in EEPROM in the signal processor. If power is removed from the signal processor, which powers the viewing head, and re-applied, the signal processor then automatically resends the stored parameters out to the S550B viewing head. In addition, at the front panel of the signal processors the operator may also select “CAL”, a semi-automatic mode which will help to speed up the S550B setup. Thus, the S550B is a dual-sensor viewing head where the gain and filter selections are adjusted and stored remotely by the P520/P522 signal processors.

Specifications: - Application: Flame Detector
- Dimensions (in.): 4.1 in. wide x 8.1 in. deep x 5.4 in. high
- Dimensions (mm): 104 mm wide x 206 mm deep x 137 mm high
- Used With: RP532A, RP532D, RP531A, RP531D, RP522A, RP522D Signal Processors
- Electrical Ratings: 22 to 26Vdc from signal processor
- Approvals, Canadian Standards Association: Certified
- Electrical Connections: Quick disconnect plug
- Approvals, Factory Mutual: Approved
- Type: UV/IR Viewing Head
- Ambient Temperature Range (F): -40 to 158 F
- Ambient Temperature Range (C): -40 to 70 C
- NEMA Rating: 4X
- Sight Pipe (NPT): 1 in.
- Purge Air Pipe (NPT): 1/2 in.
- Shutter: Electronic of IR only
- UV Gain adjustment: 0-99
- IR Gain adjustment: 0-699
- Digital Displays: Yes (2)
- Environmental, Electrical or Ingress Protection Rating: IP67

About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.
More information about Honeywell S550B:
http://dticorp.com/catalog/honeywell-iris-s550b-viewing-head-for-flame-monitor-p-160686.html

Thursday, September 12, 2013

DtiCorp.com Is Introducing The New Honeywell S87B1008 Ignition Control


Fort Lauderdale, FL – Popular online HVAC retailer DtiCorp.com (http://www.DtiCorp.com) is introducing the brand new Honeywell S87B1008 Single Rod Direct Spark Ignition Control. Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.

Features:

- Control ignition sequence and gas control operation.
- Generate high voltage potential for main burner ignition.
- Lockout after one trial for ignition if main burner fails to ignite.
- Reset from thermostat after lockout.
- Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less.

Specifications:

- Description: Provide electronic control of direct spark ignition systems used on gas fired furnaces, boilers, and other heating appliances.
- Ignition System Type: Direct Spark Ignition
- Ignition Sequence: Single trial for main burner ignition (then shut down and lockout)
- Typcial gas Control: VR8205, VR8305
- Type of Gas: Natural or LP
- Flame Sense: Single Rod
- Ignition Source: Internal high voltage spark generator
- PrePurge: None
- Ignition Trials To Lockout: 1
- Lockout Timing: 6 seconds
- Ignition Trial Time (sec): 6 Seconds
- Maximum Valve Load @ 24 Vac (Amps): 2A
- Typical Ignition Hardware: Q347A
- Dimensions: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. long
- Electrical Ratings: 24 Vac
- Frequency: 60 Hz
- Maximum Ambient Temperature (F): -40 to 175
- Includes: Alarm Terminal
- Flame Failure Response Time (sec): 0.8 sec. @ 5.0 microamp


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.

More information about Honeywell S87B1008:

http://dticorp.com/catalog/honeywell-s87b1008-single-rod-direct-spark-ignition-control-p-4681.html