Honeywell LG1093AA24 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa24-turbine-flame-sensor-p-5383.html
Industrial power generation gas turbine installations demand the superior protection provided by the Honeywell UV Flame Monitoring System. The Honeywell flame monitor system detects the ultraviolet radiation emitted by a hydrocarbon flame and produces an output signal to indicate a flame or no-flame condition. This system has delivered proven performance on General Electric (and GE licensee) gas turbines for more than 35 years. Land-based and off-shore applications include power generation, pumping stations, shipboard power generation among other industrial uses. A variety of sensors types, amplifier types and sensor cable lengths are available.
Flame monitoring of a burner has comprised the use of thermocouples, expansion tubes, and radiation sensors. Due to the extremely high flame temperatures in process boilers, monitoring of boiler flames in large furnaces has been done mainly with remotely located radiation sensors or sonic microphone pickups, which detect the frequency of the flame.
Friday, March 2, 2018
Honeywell LG1093AA25 Turbine Flame Sensor
Honeywell LG1093AA25 Turbine Flame Sensor from www.DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa25-turbine-flame-sensor-p-160701.html
Specifications:
- Geiger Mueller-type sensor phototube. Detects ultra-violet band and
1800 - 2600 angstroms. "Solar blind" and tolerant to black body
radiation.
- Two-year shelf-line, 10,000 hours MTBF with over one billion operating hours.
- Mounting Interface: 3/4 inch internal NPT.
- Control Panel Connection: Teflon shielded cable with one inch external conduit thread.
- Operating Temperature: -40°F to +350°F.
- Window Pressure Rating: 150 psig at 400°F.
- Special Certifications:
- Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D
- CE Mark: EMC Directive 89/336/EEC, ATEX Directive 94/9/EC, II 2G, EEx d IIA T3 or EEx d IIC T3 Models
AA34/35/36/44/45/46
- Cable Lengths:
- AA24/AA34: 16ft (4.9m)
- AA25/AA35: 42ft (12.8m)
- AA26/AA36: 61ft (18.6)
Specifications:
- Geiger Mueller-type sensor phototube. Detects ultra-violet band and
1800 - 2600 angstroms. "Solar blind" and tolerant to black body
radiation.
- Two-year shelf-line, 10,000 hours MTBF with over one billion operating hours.
- Mounting Interface: 3/4 inch internal NPT.
- Control Panel Connection: Teflon shielded cable with one inch external conduit thread.
- Operating Temperature: -40°F to +350°F.
- Window Pressure Rating: 150 psig at 400°F.
- Special Certifications:
- Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D
- CE Mark: EMC Directive 89/336/EEC, ATEX Directive 94/9/EC, II 2G, EEx d IIA T3 or EEx d IIC T3 Models
AA34/35/36/44/45/46
- Cable Lengths:
- AA24/AA34: 16ft (4.9m)
- AA25/AA35: 42ft (12.8m)
- AA26/AA36: 61ft (18.6)
Honeywell LG1093AA26 Turbine Flame Sensor
Honeywell LG1093AA26 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa26-turbine-flame-sensor-p-5521.html
Features:
- High sensitivity with fast response time (0.1 sec typical)
- Amplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.
- Operating distances up to 1000 feet, sensor to amplifier.
- Available with Factory Mutual approval for explosive atmospheres.
- Available with European Directive CE mark for EMC 89/336/EEC, LVD 73/23/EEC and ATEX Explosive Atmosphere 94/9/EC.
- Qualified component on General Electric turbines.
Features:
- High sensitivity with fast response time (0.1 sec typical)
- Amplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.
- Operating distances up to 1000 feet, sensor to amplifier.
- Available with Factory Mutual approval for explosive atmospheres.
- Available with European Directive CE mark for EMC 89/336/EEC, LVD 73/23/EEC and ATEX Explosive Atmosphere 94/9/EC.
- Qualified component on General Electric turbines.
Honeywell LG1093AA34 Turbine Flame Sensor
Honeywell LG1093AA34 Turbine Flame Sensor from DtiCorp.com
http://www.dticorp.com/catalog/honeywell-lg1093aa34-turbine-flame-sensor-p-160697.html
Specifications:
- Geiger Mueller-type sensor phototube. Detects ultra-violet band and
1800 - 2600 angstroms. "Solar blind" and tolerant to black body
radiation.
- Two-year shelf-line, 10,000 hours MTBF with over one billion operating hours.
- Mounting Interface: 3/4 inch internal NPT.
- Control Panel Connection: Teflon shielded cable with one inch external conduit thread.
- Operating Temperature: -40°F to +350°F.
- Window Pressure Rating: 150 psig at 400°F.
- Special Certifications:
- Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D
- CE Mark: EMC Directive 89/336/EEC, ATEX Directive 94/9/EC, II 2G, EEx d IIA T3 or EEx d IIC T3 Models
AA34/35/36/44/45/46
- Cable Lengths:
- AA24/AA34: 16ft (4.9m)
- AA25/AA35: 42ft (12.8m)
- AA26/AA36: 61ft (18.6)
http://www.dticorp.com/catalog/honeywell-lg1093aa34-turbine-flame-sensor-p-160697.html
Specifications:
- Geiger Mueller-type sensor phototube. Detects ultra-violet band and
1800 - 2600 angstroms. "Solar blind" and tolerant to black body
radiation.
- Two-year shelf-line, 10,000 hours MTBF with over one billion operating hours.
- Mounting Interface: 3/4 inch internal NPT.
- Control Panel Connection: Teflon shielded cable with one inch external conduit thread.
- Operating Temperature: -40°F to +350°F.
- Window Pressure Rating: 150 psig at 400°F.
- Special Certifications:
- Factory Mutual: Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D
- CE Mark: EMC Directive 89/336/EEC, ATEX Directive 94/9/EC, II 2G, EEx d IIA T3 or EEx d IIC T3 Models
AA34/35/36/44/45/46
- Cable Lengths:
- AA24/AA34: 16ft (4.9m)
- AA25/AA35: 42ft (12.8m)
- AA26/AA36: 61ft (18.6)
Honeywell LG1093AA35 Turbine Flame Sensor from DtiCorp.com
Honeywell LG1093AA35 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa35-turbine-flame-sensor-p-160698.html
Features:
- High sensitivity with fast response time (0.1 sec typical)
- Amplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.
- Operating distances up to 1000 feet, sensor to amplifier.
- Available with Factory Mutual approval for explosive atmospheres.
- Available with European Directive CE mark for EMC 89/336/EEC, LVD 73/23/EEC and ATEX Explosive Atmosphere 94/9/EC.
- Qualified component on General Electric turbines.
Features:
- High sensitivity with fast response time (0.1 sec typical)
- Amplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.
- Operating distances up to 1000 feet, sensor to amplifier.
- Available with Factory Mutual approval for explosive atmospheres.
- Available with European Directive CE mark for EMC 89/336/EEC, LVD 73/23/EEC and ATEX Explosive Atmosphere 94/9/EC.
- Qualified component on General Electric turbines.
Honeywell LG1093AA36 Turbine Flame Sensor
Honeywell LG1093AA36 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa36-turbine-flame-sensor-p-160601.html
Honeywell LG1093AA44 Turbine Flame Sensor
Honeywell LG1093AA44 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa44-turbine-flame-sensor-p-160699.html
Sensors are positioned to converge and the radiation magnitude received by the individual sensors is similar. A circuit means subtracts the output signals of the individual sensors of the pair, the steady and slowly varying components of flame radiation from the flame are effectively canceled leaving the rapidly varying difference signal for flame detection. The high frequency flame flickering is due to random pulses or burst of radiation from very localized sources in the flame, and there will always be a residual, varying component from the dual sensor system as long as the flame is present.
Sensors are positioned to converge and the radiation magnitude received by the individual sensors is similar. A circuit means subtracts the output signals of the individual sensors of the pair, the steady and slowly varying components of flame radiation from the flame are effectively canceled leaving the rapidly varying difference signal for flame detection. The high frequency flame flickering is due to random pulses or burst of radiation from very localized sources in the flame, and there will always be a residual, varying component from the dual sensor system as long as the flame is present.
Honeywell LG1093AA45 Turbine Flame Sensor from DtiCorp.com
Honeywell LG1093AA45 Turbine Flame Sensor from DtiCorp.com http://www.dticorp.com/catalog/honeywell-lg1093aa45-turbine-flame-sensor-p-1006.html
Honeywell LG1093AA46 Turbine Flame Sensor
Honeywell LG1093AA46 Turbine Flame Sensor http://www.dticorp.com/catalog/honeywell-lg1093aa46-turbine-flame-sensor-p-160700.html