Monday, September 27, 2010

DtiCorp.com Is Introducing 6 Honeywell R8184 Protectorelay Oil Burner Controls

Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 6 brand new Honeywell R8184 Protectorelay Oil Burner Controls. The Honeywell Protectorelay Oil Burner Controls operate the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit.



Features:



- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.

- Solid state flame sensing circuit.

- LED on terminal strip indicates system lockout.

- Remote lockout indication available on some models.

- Enclosed safety switch with external reset button.

- Manual trip lever opens safety switch for system maintenance.

- Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.

- C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required.



Specifications:



- Solid-state electronic circuitry provides low power consumption and high reliability.

- Solid-state models directly replace previous models with vacuum electron tube circuitry.

- Detectors can be mounted horizontally, vertically or at any angle. The self-checking C7012E,F models
require faceplate alignment and have integral locating reference points to assure proper shutter mechanism operation.

- Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.

- Threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame
sighting applications.

- A swivel mount is available to facilitate flame sighting.

- Models are available with a -40°F (-40°C) rating.

- Designed for use with Honeywell Flame Safeguard Controls using Honeywell Rectification (R7247A,
R7289A, R7847A1082) and Ampli-Check Rectification (R7247B, R7847B1072) Flame Signal Amplifiers.



- C7012G models available to meet BGC (British) and DIN (German) requirements.

- Incorporate UV sensor tube checking feature; used with Honeywell Dynamic Self-Check (R7247C, R7847C) Flame Signal Amplifiers.



Models available:




1. R8184G4009 Protectorelay Oil Burner Control with 45 seconds lock out timing


2. R8184G4025 Protectorelay Oil Burner Control with 45 seconds lock out timing


3. R8184G4066 Protectorelay Oil Burner Control with 15 seconds lock out timing


4. R8184G4074 Protectorelay Oil Burner Control with 30 seconds lock out timing


5. R8184G4082 Protectorelay Oil Burner Control with 45 seconds lock out timing


6. R8184M1051 Protectorelay Oil Burner Control with 45 seconds lock out timing




About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.




Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com

Monday, September 20, 2010

27 New Honeywell C7005 and Q179 Gas Pilot Burner Assemblies from DtiCorp.com

Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)

is introducing 27 New Honeywell C7005 and Q179 Gas Pilot Burner
Assemblies. Honeywell Gas Pilot Burner Assemblies include a flame rod to
prove the pilot flame. The assemblies are used with a suitable flame
safeguard control on industrial or commercial gas burners or oil burners
with gas pilots.


Features:


- Used with Honeywell controls using the flame rectification principle.

- C7005A is for continuous pilot applications.

- It includes an insulated flame rod, properly positioned relative to
the flame retention type nozzle. C7005B is similar to C7005A, but
includes an ignition electrode suitable for automatic, electric-spark
ignition, gas pilot applications.

- Individually mounted flame rod and ignition electrode in ceramic
insulators allow the head assembly to fit inside a 3-inch pipe.

- Stainless steel fins on the flame retention type pilot head provide
the correct ratio of flame rod area to ground area for maximum flame
signal, and are beneficial in stabilizing the pilot flame.

- Pilot flame retention nozzle and mixing tube are threaded internally,
1/2-14 NPT and 3/8-18 NPT, respectively, and can be assembled with
standard pipe fittings.

- Pilot can be installed in vertical, horizontal, or inclined position.


- Rajah connectors facilitate electrical connections.


Product Specifications:


- Models:

C7005A Gas Pilot and Flame Rod Assembly for continuous pilot applications; includes flame rod only.

C7005B Gas Pilot and Flame Rod Assembly for automatic pilot applications; includes flame rod and ignition electrode.


- Pilot Head:

Flame retention type with stainless steel bomb type fins. Threaded onto
1/2 x 6 inch (152 mm) pipe nipple with 1/2-14 NPT external threads.


- Type of Gas:

Models available for use with natural and propane gases.



- Insulator Brackets:

Adjustable to change location of flame rod or ignition electrode; lock securely using setscrew.


- Mixing Tube:

Inspirating (Venturi type) with primary air adjustment. Approximately
4-9/16 inches (116 mm) long, 1-3/4 inches (44.5 mm) diameter. Inlet
tapping 1/4-18 NPT; outlet tapping 3/8-18 NPT.


- Mounting:

Vertical, horizontal, or inclined.


- Dimensions:

Overall Height 13-1/2 inches (343 mm); width can be adjusted to pass through a 3-inch pipe.

Pilot Head Length 4-7/16 inches (113 mm), diameter 1-5/8 inches (41.3
mm). Spark Gap (C7005B only) 1/8 to 3/16 inch (3.2 to 4.8 mm).



- The C7005B Gas Pilot and Flame Rod Assembly includes an ignition
electrode and a flame rod. The operation of these two electrodes in a
simple electrically-operated, gas pilot installation.


- At the beginning of the starting cycle, a high voltage from the
secondary winding of the ignition transformer is applied to the ignition
electrode. A spark jumps across the outlet of the pilot burner. The
pilot gas valve is either automatically or manually opened, and the
spark ignites the gas.


- When the ignition transformer is energized, ac voltage is applied
to the flame rod through a flame safeguard control. When the pilot flame
appears, this ac voltage is changed to dc voltage through a rectifying
action. This dc voltage then operates a relay, opening the valve to the
main burner (or permitting it to be manually opened). In the event of
flame failure, flame rectification stops, the gas valves are
deenergized, the valves close, and the system shuts down.


- Approvals:

Underwriters Laboratories Inc. Listed: File No. MP268.

Canadian Standards Association Certified: C7005 only

Master file LR-95329-1.

Industrial Risk Insurers acceptable.


Models available:



1. C7005A1037 Flame Rectifier Pilot with a 0.052 in. dia. Orifice


2. C7005B1035 Flame Rectifier Pilot with a 0.052 in. dia. Orifice


3. C7005B1050 Flame Rectifier Pilot with a 0.028 in. dia. Orifice


4. Q179A1001 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


5. Q179A1035 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree right hand port and tip style


6. Q179A1050 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and T tip style


7. Q179A1076 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and 45 degree Y port and tip style


8. Q179A1092 Flame Rectifier Pilot with a 0.028 in. dia. Orifice and 45 degree T port and tip style


9. Q179A1118 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree left hand port and tip style



10. Q179A1126 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


11. Q179A1183 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and I tip style


12. Q179B1042 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and T tip style


13. Q179B1109 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree left hand port and tip style


14. Q179B1117 Flame Rectifier Pilot with a 0.025 in. dia. Orifice and 45 degree I port and tip style


15. Q179C1009 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


16. Q179C1025 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Rear Target Mount and L tip style


17. Q179C1033 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Left Side Target Mount and D tip style


18. Q179C1041 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Right Side Target Mount and D tip style



19. Q179C1058 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Left Side Target Mount and L tip style


20. Q179C1066 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Right Side Target Mount and K tip style


21. Q179C1090 Miniature Flame Rectifier Pilot with 0.016 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


22. Q179C1108 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


23. Q179D1008 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style


24. Q179D1016 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Left Side Target Mount and D tip style


25. Q179D1024 Miniature Flame Rectifier Pilot with 0.026 in. dia. Orifice, Dual Wing Right Side Target Mount and D tip style


26. Q179D1057 Miniature Flame Rectifier Pilot with 0.024 in. dia. Orifice, Single Wing Left Side Target Mount and L tip style


27. Q179D1925 Miniature Flame Rectifier Pilot with 0.016 in. dia. Orifice, Dual Wing Rear Target Mount and D tip style



About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com





Friday, September 10, 2010

DtiCorp.com Is Introducing 19 Honeywell C7012 Flame Detectors

Fort Lauderdale, FL - Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 19 Honeywell C7012 Solid State Purple Peeper Ultraviolet
Flame Detectors. Solid state electronic flame detectors for use with
Honeywell Flame Safeguard controls and amplifiers. Sense ultraviolet
radiation produced by combustion of gas, oil, coal or other fuels.


Features:


- Mount horizontally, vertically or at any angle in between.

- Provide quick electrical hookup with threaded conduit fitting and color-coded leadwires.

- Reduced nuisance shutdowns by wiring two in parallel.


- C7012E1278 5 pin Brad Harrison type (formally 41307N) mating connector not supplied nor available through Honeywell.

- C7012A,E meets NEMA 4 standards with viewing window rated to 20 psi.

- C7012C,F has an explosion-proof housing for use in hazardous atmospheres with a viewing window rated to 100 psi.


Specifications:


- Solid-state electronic circuitry provides low power consumption and high reliability.

- Solid-state models directly replace previous models with vacuum electron tube circuitry.

- Detectors can be mounted horizontally, vertically or at any angle. The self-checking C7012E,F models

require faceplate alignment and have integral locating reference points to assure proper shutter mechanism operation.

- Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.


- Threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame

sighting applications.

- A swivel mount is available to facilitate flame sighting.

- Models are available with a -40°F (-40°C) rating.

- Designed for use with Honeywell Flame Safeguard Controls using Honeywell Rectification (R7247A,

R7289A, R7847A1082) and Ampli-Check Rectification (R7247B, R7847B1072) Flame Signal Amplifiers.

- C7012G models available to meet BGC (British) and DIN (German) requirements.

- Incorporate UV sensor tube checking feature; used with Honeywell Dynamic Self-Check (R7247C, R7847C) Flame Signal Amplifiers.



Models available:


1. C7012A1145 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


2. C7012A1152 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


3. C7012A1160 120 Vac Flame Sensor, Ultraviolet, Purple Peeper


4. C7012A1186 208 Vac Flame Sensor, Ultraviolet, Purple Peeper


5. C7012A1194 240 Vac Flame Sensor, Ultraviolet, Purple Peeper


6. C7012C1042 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Explosion Proof


7. C7012E1104 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


8. C7012E1112 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking



9. C7012E1120 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


10. C7012E1146 208 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


11. C7012E1153 240 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


12. C7012E1161 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


13. C7012E1187 220 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


14. C7012E1195 110 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


15. C7012E1203 240 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


16. C7012E1245 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


17. C7012E1278 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking



18. C7012F1052 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


19. C7012G1019 220 Vac Flame Sensor, Ultraviolet, Purple Peeper


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products,
including industrial, commercial and residential parts and equipment
from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong
and more. Our online catalog is easy to navigate and search, and all
products have a picture and a description. If a customer has any
questions about a product, they can call 800-757-5999 and speak with one
of our product experts. Our mission is to offer the best prices
anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767


Web: http://www.DtiCorp.com


Friday, September 3, 2010

9 New Honeywell R7847 Flame Amplifiers from DtiCorp.com | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)

is introducing 9 New Honeywell R7847 Flame Amplifiers – Honeywell
solid state plug-in amplifiers that respond to flame detector inputs to
indicate the presence of flame when used with 7800 SERIES relay modules.
The R7847A,B Rectification Flame Amplifiers are solid state plug-in
amplifiers that respond to a rectified signal from a rectification type
flame detector to indicate the presence of flame when used with 7800
SERIES Relay Modules.


Features:


- Flame failure response time of 0.8 or 3.0 seconds.

- Flame signal strength ranges from 0.0 to 5.0 Vdc.

- Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation.

- Flame signal test jacks to measure amplifier flame signal voltage.

- Color-coded labels identify flame detection type. Dynamic Self-Check
Amplifier test the detectors and all electronic components in the flame
detection system 7800 SERIES relay module locks out on safety shutdown
with flame detection system failure.

- Compatible with existing Honeywell flame detectors (sold separately).


Product Specifications:



- Flame failure response time of 0.8 or 1 second; or 2.0 or 3.0 seconds, depending on the amplifier and relay module selected.

- Plug-in to 7800 SERIES and R7140 Relay Module through printed circuit board edge connector keyed

for proper orientation.

- Flame signal test jacks measure amplifier flame signal voltage.

- 0.0 to 5.0 Vdc Flame signal strength reading range.

- Color coded label identifies flame detection type:

* Green—rectification. Red—infrared.

* Purple—ultraviolet. Blue—pulsed rectification.

* White—optical.


- R7847B, R7848B, R7849B Dynamic Ampli-Check circuitry tests all flame
amplifier components 12 times per minute. The 7800 SERIES and R7140
Relay Module locks out on safety shutdown with amplifier failure.

- R7824C, Series 2 or greater and R7847C Series 4 or greater, pulse the shutter when signal of 1.5 Vac

is sensed. Display readings of 0.7 to 2.4 Vdc are common.

- R7824C, R7847C Dynamic Self-Check Rectification Amplifier, R7851C
Dynamic Self-Check Optical Flame Amplifier, R7861 Self-Check Ultraviolet
Flame Amplifier and R7886A Dynamic Self-Check Ultraviolet Amplifier
test the detectors and all electronic components in the flame detection
system 12 times per minute. The 7800 SERIES and R7140 Relay Module locks
out on safety shutdown with flame detection system failure.


Models available:


1) R7847A1025 Flame Amplifier, Rectification, FFRT: 0.8 sec or 1.0 sec, for 7800 Series Relay Modules


2) R7847A1033 Flame Amplifier, Rectification, FFRT: 2.0 sec or 3.0 sec, for 7800 Series Relay Modules


3) R7847A1074 Flame Amplifier, Rectification, FFRT: 0.8 sec or 1.0 sec, for 7800 Series & R7140 Relay Modules



4) R7847A1082 Flame Amplifier, Rectification, FFRT: 2.0 sec or 3.0 sec, for 7800 Series or R7140 Relay Modules


5) R7847B1023 Flame Amplifier, Rectification Ampli-Check, FFRT: 0.8 sec or 1.0 sec, for 7800 Series Relay Modules


6) R7847B1031 Flame Amplifier, Rectification Ampli-Check, FFRT: 2.0 sec or 3.0 sec, for 7800 Series Relay Modules


7) R7847B1064 Flame Amplifier, Rectification Ampli-Check, FFRT: 0.8 sec or 1.0 sec, for 7800 Series or R7140 Relay Modules


8) R7847B1072 Flame Amplifier, Rectification Ampli-Check, FFRT: 2.0 sec or 3.0 sec, for 7800 Series or R7140 Relay Modules


9) R7847C1005 Flame Amplifier, Dynamic Self Check for C7012E,F, for 7800 Series Relay Modules





About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products,
including industrial, commercial and residential parts and equipment
from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong
and more. Our online catalog is easy to navigate and search, and all
products have a picture and a description. If a customer has any
questions about a product, they can call 800-757-5999 and speak with one
of our product experts. Our mission is to offer the best prices
anywhere to our customers.



Julian Arhire

Manager DtiCorp.com

Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com



ListFree.org: Embedded data.




ListFree.org (Press Release) - Friday, September 3rd, 2010 -






Bookmark and Share



Subscribe


 




Wednesday, August 25, 2010

DtiCorp.com Is Introducing 8 Honeywell W7751 Controllers | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 8 Honeywell W7751 Unitary Controllers for Excel 5000.
The W7751B,D and F are VAV II Controllers in the Excel 10 family product
line. These VAV controllers provide pressure independent or pressure
dependent air flow control and series and parallel (induction) fan
control using single and dual duct applications. VAV systems generally
provide cool air only to the zones. The W7751 controllers provide
additional outputs that control VAV box reheat coils. The heaters can be
staged electric or modulating hot water. Supply and exhaust
pressurization control are provided on a zone basis. W7751H and J Smart
VAV Actuator are factory-integrated VAV Box Controllers with a 90 second
ML6174B Direct-Coupled Actuator in the Excel 10 family product line.


Features:


- Uses Echelon LonWorks protocol.


- W7751B,D,F use Free Topology Transceiver (FTT) networks and are
compliant with VAV device object type number 8010 functional LonMark
profile.

- Energy saving setpoint reset for electrical demand limit control.

- Actuator included with W7751H mounts directly onto VAV box damper
shaft and has up to 35 lb. in. torque, 90 degrees stroke, and 90 sec.

- Timing at 60 Hz.

- High speed 78 kilobit communications network.

- Capable of standalone operation, but uses E-Bus network communications.

- Easy user-access to the network communications jack.

- Uses enhanced microbridge-type airflow sensor with dual integral restrictor design.

- Easy user-access to airflow sensor inputs.


- Provides Proportional Integral Derivative (PID) temperature control.

- Designed for pressure independent Variable Air Volume (VAV) control.

- Floating hot water and three-stage electric or modulating hot water heat.

- Provides nonlinear floating algorithm for velocity control loops.

- Individual zone pressurization for supply and exhaust control.

- Factory configured via EEPROM with critical user parameters default values.

- Motion sensor interface for enhanced energy savings.

- Supports Terminal Regulated Air Volume (TRAV) concept.

- Pressurize and depressurize, night purge, and morning warm-up sequences supported.


- Wall module options for sensor, setpoint and bypass.

- Software selectable limits on remote setpoint adjustments.

- Three integrated 8 bit pipelined microprocessors running at 10 MHz.

- 14 bit A/D converter.

- 32K by 8 ROM/PROM, 512 bytes of EEPROM, and 2048 bytes of static RAM.

- W7751D,F mount to a standard 4 x 4 in. and 5 x 5 in. junction box or snapped to 35 by 7.5mm EN50022 DIN Rail.

- Subbase provides the slotted hole pattern for the R7450 series IRC devices (118×87 mm)


Specifications:


- When the VAV II controller is being balanced, the configuration or balancing tool may indicate stable


airflow and allow balancing before the controller has actually reached
the balancing control setpoint. During this period, if any measurements
are made of the actual airflow volume and entered while the controller
is still ramping to the airflow setpoint, erroneous balancing results
may be recorded.

- All VAV II controllers must be balanced for both minimum and maximum
airflow for highest accuracy. If the controller’s final configuration is
to be a constant volume unit, a minimum airflow balance is

recommended.

- Excel 10 VAV II Controllers must have an air flow pickup table
downloaded to ensure accurate balancing. Configuration tools do not
automatically install the flow pickup table defined for the controller.

- If VAV II Controllers are not balancing, check with the Honeywell
Authorized technician or Honeywell contractor that the flow pickup table
download to each controller has occurred.

- Anytime the controller’s airflow measurement process is to be tested or troubleshooting is attempted, the

airflow must be constant. The VAV II controller should be fixed at some
desired or stable setpoint that is not changed during troubleshooting or
testing.

- Anytime the airflow pickup tubes are disconnected from the controller, the controller should be powered

down. There is no chance of damage to the controller, but if the
controller is exposed to unusually high static pressure (< 5.0 in.
w.c.) when one pickup tube is connected there is a very slight
possibility that the


controllers sensing process will stop operating. Should this condition
be suspected, simply cycle power to the controller. It is not possible
for this condition to occur under normal operation with both airflow
pickup tubes connected to the controller.

- Physical measurement of the flow pickup pressure for the purpose of
testing is best done with an instrument capable of displaying pressure
to 0.01 ±0.005 in. w.c. Though electronic gauges and sensors often offer
the necessary accuracy, their sensitivity can cause problems in field
applications.


Models available:


1. W7751B2010 Excel 10 VAV II controller compatible Printed Wiring Board


2. W7751C1002 Excel 10 series 1000 VAV controller


3. W7751D2016 Excel 10 VAV II controller with two piece construction and an internally wired subbase


4. W7751E1007 Excel 10 series 1000 VAV controller


5. W7751F2011 Excel 10 VAV controller with two piece construction and an externally wired subbase


6. W7751G1003 Excel 10 series 1000 VAV controller



7. W7751H2025 Excel 10 smart VAV controller with a premounted ML6161 Actuator


8. W7751J2004 Excel 10 smart VAV controller with a premounted ML6161 Actuator


About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767

Web: http://www.DtiCorp.com

Wednesday, August 18, 2010

10 New Honeywell Excel 5000 Controllers from DtiCorp.com | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com)
is introducing 10 New Honeywell Excel 5000. The Excel
500 and 600 Controllers are direct-digital control,
microprocessor-based, programmable controllers that manage building
functions. An Excel 500 can include up to 18 plug-in modules including a
computer module, power supply module, optional modem module, and a
site-specific set of analog and digital input/output modules. The Excel
500 uses a standard computer module. The flexibility of Excel 500/600
easily accommodate expansion. A network can link Excel 5000 system
controllers (Excel 50, 100, 500, and 600), a Q7645A Excel Link, Q7750
Zone Manager, and a Communication System Server on a peer-to-peer
Communication Bus (C-Bus) so they can exchange data. The optional Excel
XI581/2 Operator Terminal provides an operator interface that supports
an interactive question-response dialog for easy access to messages and
controller data. The optional Excel X1584 Portable Operator Terminal
(POT) is a software tool that runs on a portable computer and is used to
install applications programs, implement on-site adjustments, and
access controller information.



Features:


- Bus-Wide MMI provides local viewing/modification of point information of all controllers attached to the Communication Bus.

- Modular design to allow expansion.

- Optional Distributed I/O for flexibility and easy installation.

- Stand-alone or networked operation for flexible use.

- Plug-in modules to use what you need.

- CARE-generated application programs for programming ease.

- Optional user interface for easy on-site changes.

- Battery-backed RAM eliminates reprogramming after power outage.


- Point trending for timely information.


Product Specifications:


- Description: Output Module

- Application: Output Module

- I/O Count: 3 three position relays

- Building Management Interface: ACSELON

- Building Management Interface: EBI

- Building Management Interface: SymmetrE

- Network Communications: C-Bus


- Network Communications: LonWorks Bus

- Commissioning Software: CARE


Models available:


1) XC5010C Excel 500 16-bit CPU module


2) XF522A Analog Output Module


3) XF523A Digital Input Module


4) XF524A Digital Output Module


5) XF525A Three Position Output Module


6) XF526 Analog Input Module



7) XF529 Digital Output Module


8) XH561 Excel 500 or 600 Universal Input/Output Module Housing


9) XH562H Universal Input/Output Blank Housing Cover


10) XP502 Power Supply Module


About Us: DtiCorp.Com (http://www.DtiCorp.com)
carries more than 35,000 HVAC products, including industrial,
commercial and residential parts and equipment from Honeywell, Johnson
Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online
catalog is easy to navigate and search, and all products have a picture
and a description. If a customer has any questions about a product, they
can call 800-757-5999 and speak with one of our product experts. Our
mission is to offer the best prices anywhere to our customers.


Julian Arhire

Manager DtiCorp.com


Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com



ListFree.org: Embedded data.



ListFree.org (Press Release) - Wednesday, August 18th, 2010 -







Bookmark and Share


Subscribe


 



Tuesday, August 10, 2010

DtiCorp.com Is Introducing 8 Honeywell C7061 Flame Sensors | ListFree.org

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com
(http://www.DtiCorp.com) is introducing 8 Brand New Honeywell C7061
Flame Sensors. Dynamic self-checking flame detector used with R7861
Dynamic Self-check Amplifiers for sensing the ultraviolet radiation
generated by the combustion of gas, oil, or other fuels. The C7061A is a
dynamic self-checking flame detector for

sensing the ultraviolet radiation generated by the combustion of gas,
oil, or other fuels. This flame detector is available in two versions:
model C7061A for use in Standard applications, and model C7061F for use
in installations requiring explosion-proof packaging. The flame detector
is designed for use with either, R7061 Dynamic Self-Check Ultraviolet
amplifier and R4348 Flame Switch or R7861A Dynamic Self-Check
Ultraviolet amplifier and 7800 SERIES Burner Programmers. These
configurations provide a closed-loop, self-checking circuit which
insures the integrity of both amplifier and flame detector. Improper
response simulated flame loss results in a safety shutdown and/or alarm.


Features:


- Oscillating shutter interrupts ultraviolet radiation reaching the UV sensor to provide the UV sensor tube checking function.

- Can be mounted horizontally, vertically or at any angle in between.

- The detector requires faceplate alignment and has integral locating
reference points to assure proper operation of the shutter mechanism.

- Field replaceable ultraviolet sensing tube and quartz viewing window.


- Models with threaded conduit fitting and color-coded leadwires allow rapid electrical installation.

- C7061A1038 or A1046 5 pin Brad Harrison type (formally 41307N) mating connector not supplied nor available through Honeywell.

- Two detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.

- Protective heat block built into mounting flange.

- Minus 40 F (-40 C) rated ultraviolet sensing tube is supplied.

- C7061E meets NEMA 4 standards with viewing window rated to 20 psi.

- C7061F has an explosion-proof housing for use in hazardous atmospheres with a viewing window rated to 100 psi.


Specifications:


- Models


C7061A: Self checking UV flame detector in standard housing.

C7061F: Self checking UV flame detector in explosion proof housing.
Designed for use with either R7061 Dynamic Self-Check Ultraviolet
amplifier and R4348 Flame Switch or with R7861A Dynamic Self-Check
Ultraviolet amplifier and 7800 SERIES Burner Programmers


- Ambient Operating temperature ratings

C7061A: -40°C to +70°C (-40°F to +160°F)“(derate ambient 1°F for every 13°F of aspirator temperature over 160°F).

C7061F: -20°C to +70°C (-22°F to +160°F)


- Storage temperature ratings:

Minus 51°C to +85°C (-60°F to +185°F)


- Voltage and Frequency:

C7061A1004 120 VAC, 50/60 Hz


C7061A1020 115/230 VAC, 50/60 Hz

C7061F1003 115/230 VAC, 50/60 Hz

The System operates correctly at a nominal voltage (-15%, +10%), 50/60 Hz.


- Flame Signal:

Measured at the flame current meter jack.

C7061 Detector: 1.4 to 5.5 micro amps (nominal).

R7061A Amplifier: 2.5 to 5.5 micro amps (nominal).

R7861A Amplifier: 1.25 to 5.0 Volts (On keyboard display module).


- Flame Signal amplifier:


R7061A Dynamic Self-Check Ultraviolet amplifier

R7861A Dynamic Self-Check Ultraviolet amplifier


- Interchangeability:

Models C7061A and C7061F are not interchangeable with other flame detector models.


- Shutter frequency:

0.2 Hz, nominal (when used in combination with 7800 SERIE).

Interrupts the line-of-sight of the detector about 12 times per minute
to provide self-checking. Any malfunction in the flame detection system
results in a safety shutdown. 1Hz nominal when used with R4348 in
combination with R7061 amplifier.


- Pressure rating of quarz viewing window:

C7061A: 138 kPa (20 psi) maximum.


C7061F: 690 kPa (100 psi) maximum


- Enclosure

C7061A: Meets IP66 enclosure requirements (indoor, outdoor protection;
rain-tight, dust-tight, hosedirected water). Optional water jacket
available.

C7061F: IP65 according to DIN 40050


- Weight

C7061A: 3.3 kg (7.3 Ib)

C7061F: 6.3 kg (13.9 Ib)


- Mounting and orientation

C7061A : Mounting flange with 3/4 inch NPT internal threads for attaching to sight pipe.


C7061F: Mounting flange with 1 inch NPT internal threads for attaching to sight pipe.


- Wiring Connections

C7061A1004: NEC Class 1 color coded leadwire.

Length: 8 ft (2.4m).

C7061A1020: Terminal block.

Threaded leadwire opening in faceplate:

1/2-14 NPSM internal threads for attaching conduit.

One brass cable gland standard with housing.


- Serviceability:


Field replaceable viewing window and ultraviolet sensing tube, coil and shutter assembly.


- Maximum cable length:

300 meter between sensor and amplifier


- Approvals:

Underwriters Laboratories Inc. Listed.

Canadian Standards Association Certified: Master File LR95329-1.

Factory Mutual Approved: 14740.01.

lndustrial Risk Insurers Acceptable.


Models available:



1. C7061A1004, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


2. C7061A1012, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


3. C7061A1020, 120 or 230 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


4. C7061A1038, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


5. C7061A1046, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


6. C7061A1053, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking


7. C7061F1003, 120/230 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


8. C7061F2001, 120 Vac Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than
35,000 HVAC products, including industrial, commercial and residential
parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy,
Grundfos, Armstrong and more. Our online catalog is easy to navigate and
search, and all products have a picture and a description. If a
customer has any questions about a product, they can call 800-757-5999
and speak with one of our product experts. Our mission is to offer the
best prices anywhere to our customers.



Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.206.0767