Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 23 brand new Honeywell Flame Detectors. The combustion flames of most carbon-based fuels emit sufficient ultraviolet radiation to enable the C7024 Solid State Purple Peeper Ultraviolet Flame Detector to prove flame presence in a combustion chamber. The detector is mounted outside the combustion chamber. Its mounting flange or union is threaded to one end of a sight pipe inserted through the wall of the combustion chamber. The ultraviolet sensing tube in the flame detector sights the flame through the pipe. When a flame is present, the UV tube in the C7024 senses the ultraviolet radiation emitted. The C7024 produces a signal that is sent to the amplifier in the flame safeguard control. The amplified signal pulls in the flame relay in the control to allow proper operation of the system. Because it is necessary for the UV sensing tube to actually see the flame, it is best to locate the detector as close to the flame as physical arrangement, temperature, and other restrictions permit.
Features:
- Use with R7824C Dynamic Self-Check Flame Signal Amplifier.
- Circuitry provides low power consumption and high reliability.
- Mount horizontally, vertically or at any angle in between.
- Field-replaceable UV radiation sensing tube and quartz viewing window.
- Quick electrical installation with threaded conduit fitting and color-coded leadwires.
- Reduce nuisance shutdowns by wiring two in parallel.
- Oscillating shutter interrupts UV radiation using the R7824C amplifier.
- C7024E meets NEMA 4 standards with viewing window rated to 20 psi.
- C7024F has an explosion-proof housing for use in hazardous atmospheres with a viewing window rated to 100 psi.
Specifications:
- Ambient Temperature Ratings (outside the case): C7024E,F: -20° F to +175° F (-29° C to +79° C).
- Storage Temperature Ratings: -60° F to +175° F (-51° C to +79° C).
- Housing: Violet, cast aluminum cover; mounting flange with heat block and faceplate are separate to provide heat insulation and sealoff. Meets NEMA 4 enclosure requirements (indoor, outdoor protection; rain-tight, dust-tight, hose-directed water).
- Mounting: Mounting flange with 3/4 inch NPT internal threads for attachment to sight pipe.
- Wiring Connections: NEC Class 1 color-coded lead-wires, 8 feet (2.4 meters) long.
- Serviceability C7024E and F: Field replaceable viewing windows and ultraviolet sensing tube, self-checking coil and shutter assembly.
- Approvals: For use in hazardous locations; Class 1, Groups C and D; Class 2, Groups E, F and G; File no. E34649; Canadian Standards Association Certified.
Models Available:
- C7024 Solid State Purple Peeper Ultraviolet Flame Detector.
24 Vdc solid state electronic flame detectors for sensing the ultraviolet radiation emitted by the combustion of most carbon containing fuels, such as natural gas, LP gases, and oil.
1. C7024E1001 24 Vdc Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, 24 Vdc
2. C7024F1009 24 Vdc Flame Sensor, Ultraviolet, Purple Peeper, Self-Checking, Explosion Proof, 24 Vdc
- C7027 Minipeeper Ultraviolet Flame Detector
Compact Flame Detector for use with flame safeguard controls with ultraviolet amplifiers.
3. C7027A1023 Flame Sensor, Ultraviolet, Minipeeper
4. C7027A1031 Flame Sensor, Ultraviolet, Minipeeper
5. C7027A1049 Flame Sensor, Ultraviolet, Minipeeper
6. C7027A1056 Flame Sensor, Ultraviolet, Minipeeper
7. C7027A1064 Flame Sensor, Ultraviolet, Minipeeper
8. C7027A1072 Flame Sensor, Ultraviolet, Minipeeper
9. C7027A1080 Flame Sensor, Ultraviolet, Minipeeper
10. C7027A1114 Flame Sensor, Ultraviolet, Minipeeper
- C7035 Minipeeper Ultraviolet Flame Detector
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers.
11. C7035A1023 Flame Sensor, Ultraviolet, Minipeeper
12. C7035A1031 Flame Sensor, Ultraviolet, Minipeeper
13. C7035A1049 Flame Sensor, Ultraviolet, Minipeeper
14. C7035A1056 Flame Sensor, Ultraviolet, Minipeeper
15. C7035A1064 Flame Sensor, Ultraviolet, Minipeeper
16. C7035A1080 Flame Sensor, Ultraviolet, Minipeeper
- C7044 Minipeeper® Ultraviolet Flame Detectors
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers.
17. C7044A1006 Flame Sensor, Ultraviolet, Minipeeper
- C7927 Solid State Ultraviolet Flame Detector
The Solid State Ultraviolet Flame Detectors detect the ultraviolet radiation emmited by combustion flames. The flame detectors are used with Honeywell flame safeguard controls to provide flame supervision for gas, oil, or combination gas-oil burners.
18. C7927A1016 Electronic Ultraviolet Flame Detector
- C7961 Ultraviolet Flame Detector
A self-checking flame detector using a solid state UV sensor to detect ultraviolet radiation in flames for supervision of gas, oil or combination gas-oil burners.
19. C7961E1006 Dynamic Self-checking Solid State Sensor Ultraviolet Flame Detector
20. C7961E1022 Dynamic Self-checking Solid State Sensor Ultraviolet Flame Detector
21. C7961F1004 120 Vac Dynamic Self-checking Ultraviolet Flame Detector
- C7962 Visible Light Flame Detector
The C7962B Visible Light Flame Detector detects the visible light emitted by fuel oil combustion flames. The C7962B Detector is used with Honeywell Flame Safeguard controls to provide fuel oil flame supervision in commercial and industrial burners.
22. C7962B1002 Visible Light Flame Detector
23. C7962B1010 Visible Light Flame Detector
About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.
Julian Arhire
Manager DtiCorp.com
Phone: 954.298.2515
Fax: 954.206.0767
Web: http://www.DtiCorp.com