Showing posts with label R700A1000. Show all posts
Showing posts with label R700A1000. Show all posts

Monday, September 19, 2011

DtiCorp.com Is Introducing 10 Honeywell Signal Processors

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 10 brand new Honeywell Signal Processors. Honeywell has a wide array of discriminating flame monitoring systems for industrial and difficult flame detection applications. Honeywell has teamed with IRIS Systems to distribute industrial flame detection systems. Tailor made for the unique demands of industrial processes, the CS550B dual UV/IR viewing head delivers flame discrimination in the toughest environments. With automatic setup, three channels and the ability to monitor UV and IR flame components simultaneously or separately, the RP532 signal processor offers improved burner up time and reliability. Honeywell industrial flame monitoring by IRIS Systems provides the perfect blend of form, function and flame detection.


 


Flexible Programming:


 


- Three methods of viewing head programming offer user flexibility; automatic, manual or factory defaults. Signal processors have keypads (model dependent) or may be connected to FlameTools software. Each viewing head has independent configuration. Certain models allow two sets of configuration data per viewing head. The RP531 processor has an available detachable programming plate, which reduces cost on large installations. With the plate, the RP531 has the same functionality of the RP532 processor.


 


X-Ray and Gamma Ray Immune:



 


- All viewing heads are immune to X-Rays and Gamma rays, making them ideal for myriad industrial applications.


 


Flexible Application:


 


- Wide array of products to meet broad industry needs


- Signal processors available in AC or DC versions


- Universal AC power inputs: 85-265VAC, 50/60Hz


- Independent configuration for each sensor


- FM and CSA approved



- Hazardous location viewing head models: Class 1, Div 2, Groups A, B, C & D, T5 and T4A


- Proportional 0/4-20mA flame signal output


- Flame and self-check relays


- Viewing head adjustable UV and IR gain settings


- Viewing head temperature indication


- Multiple high pass IR flicker frequency settings


- Electronic shutter for viewing head self-check


- Quick disconnect cable connection included



- Compact UV and IR detectors perfect for pilot monitoring


- UV Flare stack application specific model


 


Dual UV/IR Viewing Heads:


 


- Dual UV and IR sensing capabilities are housed within the same detector to provide application flexibility. Their ability to discriminate between all types of fuels, the main flame and unwanted background, make them uniquely suited for multiple industrial processes. Monitor UV and IR simultaneously or separately with the RP532 signal processors.


 


Individual UV and IR Viewing Heads:


 


- Multiple housing sizes and gain settings in both UV and IR to fit your application. Perfect for single and multiple burner applications and pilot monitoring.



 


Key Application Attributes:


 


- Lifecycle Costs: Separate signal processor and viewing head for ease of maintenance


- Set-Up:


> Wide spectral response for a variety of difficult to site applications


> Adjustable “Flame On” and “Flame Off” points for added discrimination


> Digital processing means you work with numbers – reduced field set-up time



> Ability to set-up and store settings in memory for ease of replacement


> Wide gain adjustment and multiple flicker frequency setting capability to prevent flame out in single or multiple burner applications


 


Burner Management System Interface:


 


- Each signal processor has a 0/4-20mA scalable flame signal output, two SPDT or SPST flame relays, and one SPDT or SPST self-check relay. The RP532 and RP531 signal processors also have a 24VDC auxiliary output and three N.O. alarm relays. Signal processors may also be linked to BMS using Modbus RTU protocol for monitoring and diagnostics.


 


Remote Configuration, Monitoring, Diagnostics:



- Easily interface multiple signal processors through FlameTools software for remote configuration, monitoring and diagnostics. Each signal processor is Modbus RTU capable with selectable parity and baud rate settings. Link up to 31or 63 signal processors (model dependent), in a single daisy chain loop, to FlameTools software. Refer to the applicable manual for connection method (RJ-11, RJ-45, 2-wire twisted pair, stereo jack).



 


Models available:


 


1. RP532A1026


2. RP532D1034


3. RP531A1002


4. RP531D1024


5. RP522A1004



6. RP522D1018


7. RP222A1006


8. R700A1000


9. R700S1012


10. R800S1008


 


 



About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.


 


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.484.5155

Web: http://www.DtiCorp.com

Tuesday, August 30, 2011

DtiCorp.com Is Introducing 10 Honeywell IFMS Signal Processors

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 10 Brand New Honeywell IFMS Signal Processors. Honeywell’s flame monitoring systems are perfect for industries such as petroleum and petrochemical, power generation, pulp, paper and metals processing. Their ability to discriminate in the toughest environments tailors them for industrial process boilers, black liquor recovery boilers, co-generation boilers, grate fired boilers, cement or lime kilns, Claus reactors (H2S), thermal oxidizers and gas turbines. Honeywell’s industrial flame monitoring systems are uniquely suited for multiple burner applications, exotic fuels, hostile environments and burner types including combination, low NOx, tilting, opposed fired, hydrogen, duct and register. With the RP532 signal processors, the UV and IR flame components may be monitored simultaneously or separately. Additionally, the RP532 processors allow a total of three viewing heads; two individual CS55xB series detectors and one CS700/CS800 detector, which may be used for pilot monitoring. A detachable programming plate on the RP531 saves on large installations. Processors are compatible with Modbus communications for remote monitoring and diagnostics.


 


Features RP532/RP531:



 


- The RP532/RP531 are 3-channel, signal processors which amplify and conditions the viewing head signal for use with a burner management system. It provides a proportional 0/4-20mA output signal per attached viewing head as well as two SPDT flame relay outputs, one SPDT self-check relay output and one N.O. alarm relay output per channel. Allows a total of 3 viewing heads; two individual CS55xB and one CS700/CS800, which may be used for pilot monitoring. The CS550B UV and IR flame components may be monitored simultaneously or separately.



 


 


Features RP522:


 


- The RP522 is a 2-channel, signal processor which amplifies and conditions the viewing head signal for use with a burner management system. It provides a proportional 0/4-20mA output signal based on the currently used viewing head as well as two SPDT flame relay outputs and one SPDT self-check relay output. Allows 2 CS55xB viewing heads at a time with a toggle between channels. Its 4-digit alphanumeric display and 11 push buttons facilitate viewing head programming, monitoring and diagnostics.


 


 


Features R700/800:


 


- The R700/800 is a compact 1-channel, signal processor which amplifies and conditions the viewing head signal for use with a burner management system. It provides a proportional 0/4-20mA output signal based on the connected viewing head as well as two SPDT flame relay outputs and one SPDT self-check relay output.



 


Features RP222:


 


- The RP222A is a 1-channel, signal processor which amplifies and conditions the viewing head signal for use with a burner management system. Used for continuous UV flare stack monitoring to ensure no unburned toxic or waste gases are released into the atmosphere. Its 4-digit alphanumeric display and 11 push buttons facilitate viewing head programming, monitoring and diagnostics.




 


Models available:




 


1. RP531A1002 AC Signal Processor



 


2. RP531D1024 DC Signal Processor


 


3. RP532A1026 AC Signal Processor


 


4. RP532D1034 DC Signal Processor



 


5. RP522A1004 AC Signal Processor


 


6. RP522D1018 DC Signal Processor


 


7. R700A1000 AC Signal Processor



 


8. R700S1012 DC Signal Processor


 


9. R800S1008 AC Signal Processor


 


10. RP222A1006 Watchdog Signal Processor



 


 


 


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.


 


Julian Arhire

Manager DtiCorp.com

Phone: 954.484.2929

Fax: 954.484.5155

Web: http://www.DtiCorp.com



 


###