Monday, January 2, 2012

Five Factors To Energy Efficiency

One of the most popular ways of improving building energy efficiency today is through a lighting systems upgrade. New, energy-efficient lighting systems offer the potential of reducing lighting energy requirements by 35 to 50 percent, with additional savings being realized in reduced air conditioning costs as lower lighting system energy use translates into reduced cooling loads.


When considering energy-efficient lighting systems, facility executives can select from a wide range of options, including fluorescent lamps, compact fluorescent lamps, electronic ballasts, efficient fixture designs and automatic lighting controls. While each of these components is important to the overall operating efficiency of the system, none is more important than the ballast selected. Selecting the proper ballast can make the difference between a lighting system that is simply more efficient than the one it replaced, or one that is highly energy efficient.



All lighting system upgrades today involve replacement of the ballasts. In most cases, the upgrade involves moving from the older magnetic ballast to one of the newer electronic ballasts. Electronic ballasts offer improved operating efficiency over magnetic ballasts, reducing ballast energy requirements by an average of 35 percent. But not all electronic ballasts are created equal. Manufacturers have developed a number of different ballast designs with different characteristics for use in different applications. There are five major ways in which ballast selection will impact the energy performance of the lighting system. To achieve optimal performance from the new lighting system, ballasts must be carefully selected to match the needs of the space.



  1. Electronic Ballast Efficiency

    Simply stated, electronic ballasts are significantly more energy efficient than their magnetic counterparts. As a result, the manufacture of magnetic ballasts will most likely be curtailed for general purpose lighting applications.The improvement in energy efficiency achieved by electronic ballasts comes as a result of several factors, including lower internal losses and higher operating frequencies. Magnetic ballasts suffer from core losses that are inherent in the design and operation of the ballast. Electronic ballasts operate without the need for windings and magnetic fields, thus eliminating magnetic losses completely.


    Electronic ballasts also operate at a higher frequency than magnetic ballasts. Magnetic ballasts operate at line frequency, 60 Hz. This means that the arc that excites the phosphors on the inside surface of the fluorescent tube is triggered 60 times each second. Electronic ballasts operate at frequencies ranging from 20 to 60 kHz. At these higher operating frequencies, the arc excites the phosphors for a longer period of time, resulting in the generation of 10 to 15 percent more light for the same energy use.


    Operating at a higher frequency also eliminates one of the most common complaints associated with fluorescent lamps: flicker. With the arc being triggered at 60 times per second with magnetic ballasts, some people can detect a flicker in the light output of the lamps. Electronic ballasts, with their higher operating frequency, completely eliminate this flicker. While the lamps are still switching on and off with the arc, the higher operating frequency makes it impossible for the eye to detect.



  2. Ballast Factor


    One of the most frequently overlooked yet important items when selecting lighting system components is the ballast factor. The ballast factor is a measurement that rates the relative light output of a ballast with respect to the light output of the same lamp operated by a reference ballast. The higher the ballast factor, the higher the light output of the lamps. The lower the ballast factor, the lower the light output of the lamp and the lower the energy use of the system. The ballast factor is dependent on both the ballast selected and the lamp installed.The ballast factor of the units selected for a particular installation will significantly impact the total light output and energy use of the lighting system. While magnetic ballasts were available in a narrow range of ballast factors, between 0.925 and 0.975, electronic ballasts are available in a wide range of ballast factors — from as low as 0.73 to as high as 1.2. This allows facility executives to select ballasts that provide a wide range of light output.


    Consider a lighting system upgrade where fixtures with magnetic ballasts and T-12 lamps are replaced on a one-for-one basis. If the lighting levels in the existing system were adequate, simply replacing the fixtures with ones using electronic ballasts with a ballast factor of 1.0 and T-8 lamps would reduce energy use, but it would result in an increase in lighting levels. Selecting a ballast with a ballast factor of 0.88 would reduce lighting system energy use even further while maintaining the original lighting levels within the space. A higher ballast factor would increase overall lighting levels, while a lower ballast factor would reduce lighting levels and energy use.


    It should be noted that ballast factor can impact lamp life. High ballast factors generally shorten lamp life and accelerate lamp lumen depreciation. In system designs, these factors must be evaluated against the cost of having to alter the layout of the lighting fixtures.


    By selecting a ballast with the proper ballast factor rating for the lamps that will be used allows facility executives to control both light output and lighting system energy use.



  3. Dimming

    With magnetic ballasts, dimming was an option, but it was not cost effective in most applications. Dimming controllers for magnetic ballasts were bulky, expensive and not very effective. Most systems could not reduce light output much below 50 percent of full brightness. Dimming tended to increase the problems associated with lamp flicker. Many systems required lamps to be started at full brightness, then dimmed to the desired level. As a result, most applications that required dimming yet wanted the efficiency of fluorescent lamp operation installed two separate lighting systems — one fluorescent and one incandescent.Dimming electronic ballasts have eliminated the problems associated with trying to dim magnetic ballasts. Controllers are small and inexpensive. Light output can be controlled to as low as 5 or 10 percent of full brightness. Flicker at low light levels is eliminated due to the high operating frequency of the ballasts. Costing approximately 35 to 50 percent more than conventional electronic ballasts, this new generation of electronic ballasts has made fluorescent lamp dimming practical, efficient and affordable.


    Most dimming electronic ballasts are controlled by a 0-10 volt DC signal from the controller. Some models make use of AC line-phase controller signals, eliminating the need for special control wiring.


    Dimming electronic ballasts can be used in any application where dimming is desirable, such as in meeting rooms. While use of dimming ballasts in these applications will save energy by eliminating the need for a separate incandescent system, the real potential for energy savings comes from applications that can make use of natural light.



    In spaces with even moderate areas of exterior glass, natural light is available for use in lighting the space. To be used effectively though, there must be a way to automatically sense the total light level in the space and adjust the light output of the fluorescent fixtures as the amount of natural light varies. Dimming electronic ballasts give facility executives that capability.


    The typical dimming system uses a sensor to measure the overall lighting level in the space. The sensor, connected to the dimming controller, regulates the light output of the fluorescent fixtures to keep the total light levels constant. A single controller can be connected to all dimming ballasts, or multiple controllers can be connected to individual banks of ballasts based on their distance from the glass. The result will be a decrease in lighting energy requirements of 35 to 75 percent for the typical office application.



  4. Rapid-Start vs. Instant-Start

    Electronic ballasts, like the older magnetic ballasts, are available in two basic types: rapid-start and instant-start. Selection of the ballast type impacts overall energy use because of differences in the operation of the ballasts.All fluorescent lamps need a means of starting the lamps as well as regulating their operation once started. Rapid-start lamps have two circuits. One circuit controls normal operation of the lamp, and the second provides a low voltage to the lamp’s electrodes. This low voltage heats the electrodes to between 70 and 100 degrees Celsius in a few seconds, allowing the lamp to light. Once lit, most rapid-start ballasts continue to supply the voltage to the electrodes, resulting in an energy use of two to three watts per 40 watt lamp.


    Instant-start ballasts do not heat the lamp’s electrodes to start them. Instead, they temporarily apply a high voltage to the lamp that strikes the arc. Once the lamp is lit, the high voltage is turned off. As a result, energy requirements are reduced. This improvement in energy performance comes with a penalty. The use of high voltage to start the arc accelerates erosion of the emissive coating on the lamp’s cathode, decreasing lamp life. Compared to rapid-start ballasts, instant-start ballasts have a lamp life that is approximately 25 percent shorter. The more frequently the lamp is started, the shorter the lamp life.


    The decision to use a rapid-start or instant-start ballast is usually made based on the application. Applications that are switched more frequently, such as those in areas controlled by occupancy sensors, are better suited for rapid-start ballasts. Applications where lights burn for longer times per start can benefit from the energy savings produced by instant-start ballasts, without significantly reducing relamping intervals.


    A third type of electronic ballast is becoming more common: the programmed-start ballast. Programmed-start ballasts offer the energy efficiency of instant-start ballasts without sacrificing lamp life.


    Programmed-start ballasts apply a low voltage to the lamp’s electrodes for starting, like instant-start ballasts. Unlike instant-start ballasts, programmed-start ballasts turn off that voltage once the lamp is lit. By turning off the voltage, these ballasts achieve the energy efficiency of instant-start ballasts, while providing the lamp life of rapid-start ballasts. While programmed-start ballasts are relatively new, they are projected to replace most rapid-start units.




  5. Power Factor

    Power factor is the ratio of active power in a circuit to apparent power. In purely resistive loads, the power factor in the circuit is 1.0. But as electrical loads are added to the circuit that are inductive, such as those from induction motors and ballasts, there is a phase shift in the circuit between the current and the voltage, and the power factor decreases. In most commercial and institutional facilities, the overall power factor is typically between 0.85 and 0.97. In industrial applications, particularly those having a large number of induction motors, it can fall to 0.75 or lower.Power factor impacts the current-carrying capacity of a circuit and the cost of electricity. Depending on the rate structure in effect for the facility, low power factor can carry a significant penalty, costing facilities thousands of dollars each month.


    Power factor is important when considering electronic ballasts because they can cause reductions in overall power factor by distorting the current wave shape. These distortions are measured by the unit’s total harmonic distortion (THD). The higher the THD, the greater the ballast’s impact on power factor. Correcting this distortion is difficult and expensive. Although the load drawn by a single electronic ballast is very low, given the number of ballasts that may be installed in a particular facility, their overall impact on system power factor can be significant and costly.


    Electronic ballasts that limit THD and therefore the impact on power factor tend to cost more than those with a higher THD, but their additional first costs can be quickly recovered, particularly in applications with a high-cost penalty for low power factor and a high lighting load. High THD generated by electronic ballasts and other sources can also cause problems within other electrical equipment in the facilities, such as the overheating of induction motors and interference in office equipment.


    For most applications, limiting electronic ballast THD to values of less than 20 percent will avoid problems with other equipment and low power factor. Electronic ballasts are available with THD ratings of below 10 percent for specialized applications.

Tuesday, December 13, 2011

Planning And Coordination For HVAC Upgrades

Building owners don’t upgrade HVAC systems simply because they want the latest HVAC technologies; rather, they are looking to correct perceived shortcomings with existing systems. That means the jumping off point should be a comprehensive assessment of the existing system. A detailed survey and inspection of all major system components should assess age, condition, efficiency and expected remaining useful life. This should include a review of original construction drawings and maintenance and repair records. Performance testing or non-destructive testing may be warranted for major equipment components or systems, including piping and ductwork.


It is important to analyze the existing system to determine whether the system is causing comfort problems. Many HVAC systems installed in the 1950s and 1960s were only intended to provide a moderate degree of cooling. No one expected a system to provide a constant temperature year-round irrespective of outside conditions.


Since high energy costs often justify HVAC upgrades, historical energy consumption should be compared against industry benchmarks of dollars or BTUs per square foot for similar types of facilities. This comparison will show how efficient a building is and will identify possible target values for improvement. It may also indicate that, although an HVAC system is 25 or more years old, overall operating costs may be comparable to newer buildings, so that a complete system replacement may not be warranted based on energy savings. In this case, replacement of selected components might be the best approach.


For some equipment, such as centrifugal chillers, current equipment is significantly more efficient than units installed 20 or more years ago, using 30 to 40 percent less energy than older models. However, depending upon the hours of operation of the equipment, these savings alone may not justify replacement because of the high capital costs of new equipment.


Another consideration in evaluating an existing system is whether it uses an obsolete technology. Building automation systems have evolved considerably over the last 10 to 15 years. Even with systems that are functioning reasonably well, it may be difficult to get parts or to find service personnel familiar with older technologies. In addition, new systems may have capabilities that the older systems lack but that would enhance mechanical system operation and improve occupant comfort.


Compliance with codes and regulations is another key issue. Buildings built from the late ’70s to the mid ’80s were often designed to provide lower outside air quantities than required by current codes. Replacement of an individual HVAC system component may not necessitate compliance with the new codes; however, this may be desirable to alleviate concerns that lower outside air quantities may lead to indoor air quality problems.



A comprehensive HVAC system analysis is necessary to evaluate the impact of increasing the outside air rate. It is usually not as simple as rebalancing the air handling systems to provide additional outside air. Increasing the outside air will increase heating and cooling loads, which the existing heating and cooling plant and related distribution systems may not have adequate capacity to serve.


In the event a comprehensive system replacement is to be undertaken, compliance with the current codes will likely be required. HVAC upgrades must be carefully evaluated to determine the full extent of code-required upgrades; this work could make the project significantly more expensive than originally expected.


Consider one owner who was contemplating a major building renovation, including mechanical system upgrades. The existing water-cooled air-conditioning units on each floor were not sized to handle the quantities of outside air currently required. Although the equipment was in fair condition and could likely have continued to operate for several years, the owner elected to replace the units so the building would meet the new ventilation standard, as well as to avoid future disruption if replacement was required after the building was fully occupied. As a result, other system components, such as cooling towers and pumps, also had to be replaced.


Environmental regulations may influence HVAC upgrades. In 1996, the Clean Air Act mandated a ban on the manufacture of CFC (chlorofluorocarbon) refrigerants, which were used in virtually all large chillers produced up until the early ’90s. Some CFC refrigerants are still relatively widely available on a recycled basis; others are scarce or are very expensive. An owner with a CFC chiller should consider refrigerant issues in deciding whether to replace the equipment.


The Right Approach


After the system assessment is completed, a key question is whether the major problems can be addressed by replacing components or if there are inherent limitations in the system that cannot be rectified without a major system renovation or replacement.


A major advantage to a systems approach is that it makes it possible to redesign and optimize the HVAC system. For example, a new HVAC system may be able to utilize smaller ductwork than that which presently exists. In an office building with a congested ceiling plenum – where additional space is needed for distribution of data cabling or new fire sprinkler systems – this may be a significant benefit. It may also be possible to design a new system to correct inherent comfort problems with an existing system, such as limited ability to control temperatures on a localized basis.



A variation of the systems approach is to combine HVAC system upgrades with other building upgrades, such as lighting retrofits. Upgrading existing lighting systems to more energy efficient lamps and ballasts will reduce the cooling load for many facilities. This may enable new HVAC systems to be downsized, with a corresponding reduction in installation costs as well as operating costs.


Future building uses must be considered as part of every HVAC upgrade project. For example, if a single-tenant building with one operating schedule is to be converted to a multi-tenant building with a wide variety of schedules and cooling requirements, the new use may require multiple smaller systems. Changing to a different use type, such as from retail to office, will also have major implications for equipment size and configuration because of different ventilation, load and control requirements.


Even with replacement of individual system components, future uses must be considered. For example, with replacement of a cooling tower dedicated to a central chilled water plant, it may be desirable to install additional capacity that can be utilized to serve individual tenant supplemental cooling equipment.


Potential Pitfalls


HVAC upgrades often have significant implications for other building systems. Changing the HVAC system will often require major electrical distribution modifications. If the electrical distribution system consists of obsolete equipment that can not be expanded or if it does not meet current codes, significant additional upgrades to the electrical system may be required, at substantial cost.


Operations and maintenance requirements will often be affected by HVAC upgrades. Usually, maintenance requirements will initially decrease when new systems are installed. However, sometimes operations and maintenance requirements of a new system may require major changes in practices or personnel. Existing operating personnel may not have the skills to operate and maintain the new systems, or may not have the required licenses from the local jurisdiction. This may necessitate some combination of training, hiring or outsourcing. Similar issues may arise for service contractors. Even if the firm that worked on the original systems did a good job, it is important to verify that they have the skills and experience to maintain the new system.


Physical building constraints will almost always have a major influence on HVAC upgrades. A new HVAC system may require more equipment room space or vertical shaft space for ductwork or piping, or may require additional space in other locations that must be taken away from occupied areas. This may have a significant impact on the functionality of the space or may reduce rental income.



A primary consideration prior to undertaking any building upgrades is the potential disruption to occupancy. For HVAC systems, major upgrades may take some or all of the system out of service for an extended period. Unless the building is unoccupied, this may not be a realistic course of action. Often, partial system replacements can be engineered and phased so that work is limited to unoccupied portions of a facility or only occurs during nights and weekends when the facility is not occupied. However, to accomplish this, the existing system must be carefully evaluated to reuse as much of it as possible, particularly within occupied spaces.


Project planning should also consider seasonal heating and cooling requirements. Ideally, replacement of heating equipment should occur during the cooling season and vice versa. If this is not possible, large central systems with multiple units serving a common load may be able to run most of the time with a portion of the units operational so that equipment can be replaced one unit at a time. Project schedules must also consider manufacturer lead times, which can be four months or longer for major equipment such as large chillers or boilers.


An HVAC upgrade project is a significant business decision requiring a major capital investment. The results of an engineering assessment may suggest that a complete system replacement or major upgrade is the best course of action but if an acceptable return on investment cannot be demonstrated to the owner, this approach will frequently not be approved. The rationale for an upgrade may not always be direct savings in energy or operating costs, but may also include improved marketability or higher lease rates for rental property if the upgrade helps to reposition the property along with other functional and aesthetic renovations. Intangible considerations such as improved occupant comfort or higher occupant productivity should also be taken into account. Given the magnitude of the financial impact and the long life of the equipment involved, it is advisable to seek the services of a qualified engineering professional to help guide the evaluation and planning process.




Julian Arhire is a Manager with DtiCorp.com – DtiCorp.com carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more.

Tuesday, June 14, 2011

Energy Efficiency And HVAC Technology

The following overview offers a quick reference to key considerations with some of the most effective technologies. As with lighting, trial installations are a good idea; so is working with manufacturers and distributors.

Getting the most from HVAC controls

Because a building's performance can be dramatically improved by installing and fully using HVAC controls, it is essential to understand and correctly use those controls. The place to start is with a close look at what is really transpiring in your building, 24 hours a day, seven days a week.

What is happening with each piece of equipment? On holidays? Weekends? As the seasons change, do your operations change? It is important to understand where and how energy is being consumed in order to identify where waste is occurring and where improvements can be implemented. Then it is imperative to ask, "What exactly do I want these controls to do?"

Energy management systems (EMS) are designed to run individual pieces of equipment more efficiently and to permit integration of equipment, enhancing performance of the system. In a typical EMS, sensors monitor parameters such as air and water temperatures, pressures, humidity levels, flow rates, and power consumption. From those performance points, electrical and mechanical equipment run times and setpoints are controlled.

Seven-day scheduling provides hour-to-hour and day-to-day control of HVAC and lighting systems and can account for holidays and seasonal changes. As the name implies, night temperature setback allows for less cooling in summer and less heating in winter during unoccupied hours.

Optimal start/stop enables the entire system to look ahead several hours and, relative to current conditions, make decisions about how to proceed; this allows the system to ramp up slowly, avoiding morning demand spikes or unnecessary run times.

Peak electrical demand can be controlled by sequencing fans and pumps to start up one by one rather than all at once and by shutting off pieces of HVAC equipment for short periods (up to 30 minutes), which should only minimally affect space temperature. Economizers reduce cooling costs by taking advantage of cool outdoor air. Supply-air temperature-reset can prevent excessive reheat and help reduce chiller load.

An EMS can provide an abundance of information about building performance, but someone has to figure out what they want the EMS to do and then give it directions. Calibrating controls, testing and balancing are key to any well-maintained HVAC system, but are especially critical to optimize control efforts.

Variable speed drives and energy-efficient motors

Variable speed drives (VSDs) are nearly always recommended as a reliable and cost-effective upgrade.

VSDs are profitable where equipment is oversized or frequently operates at part-load conditions. Savings of up to 70 percent can be achieved by installing VSDs on fan motors operating at part-load conditions. They may be applied to compressor or pump motors and are generally used in variable air volume (VAV) systems. They are also cost effective in water-side applications. Backward-inclined and airfoiled fans are the best VSD candidates.

Air-handler configurations controlled by variable inlet vanes or outlet dampers squander energy at part-load conditions. Using throttle valves to reduce flow for smaller pumping loads is also inefficient. The efficiency of motors begins to drop off steeply when they run at less than 75 percent of full load; they can consume over twice as much power as the load requires. VSDs operate electronically and continually adjust motor speed to match load.

The power to run the VSD is proportional to the cube of the speed (or flow), which is why this technology is so efficient. If the speed is reduced by just 10 percent, a 27 percent drop in power consumption should result. A VSD pilot study performed by EPA found that VSD retrofits realized an annual average energy savings of 52 percent, an average demand savings of 27 percent and a 2.5-year simple payback.

Perform harmonic, power factor, electric load, and torsional analyses before selecting a VSD. Though harmonic and power factor problems are not common in VSD applications, VSDs should generally be equipped with integral harmonic filters (or a three-phase AC line reactor) and internal power factor correction capacitors (or a single capacitor on the VSDs' main power line). In general, this equipment is not standard and must be specified.

Improved design and better materials enhance the performance of energy-efficient motors, which use 3 to 8 percent less energy than standard motors; units with efficiencies of 95 percent are available.

To achieve maximum savings, the motor must also be properly matched with its load, increasing run time at peak efficiency. Motors operate best when running at 75 to 100 percent of their fully rated load; motors routinely operating below 60 percent of rated capacity are prime candidates for retrofit. For motors whose loads fluctuate, VSDs should also be considered.

Smaller, more efficient motors are integral to a system downsizing stratagem; downsizing a 75 horsepower standard motor to a 40 horsepower energy-efficient model will result in energy savings of 15 percent.

Some energy-efficient motors have less "slip" than standard-efficiency motors, causing energy-efficient motors to run at slightly higher speeds; consider a larger pulley to compensate for the higher speed and to maximize energy savings. Installing a new pulley or adjusting the existing one can also be an alternative to a VSD when the cost for the VSD is prohibitive or the load has been reduced.

Improving fan system performance

A common way to improve the efficiency of the air distribution system is to convert constant air volume (CAV) systems to VAV. One authority on energy issues, E-Source, reports that "typical (VAV) air flow requirements are only about 60 percent of full CAV flow."

VAVs respond to load requirements by varying the volume of the air through a combination of pressure controls and dampers rather than by varying the air's temperature. According to the air pressure, fan power and volume of conditioned air are reduced, thus increasing energy efficiency. Of course, it is crucial to maintain indoor air quality (IAQ) when altering air handling systems.

To maximize savings, VAV components such as VSDs, variable-pitch fan blades, diffusers, mixers, and VAV boxes must be operating properly; careful zoning is also required to achieve VAV optimization.

E-Source recommends considering the following VAV retrofit procedures:

• complete load reduction measures and calculate the maximum and minimum air flow requirements,


• measure existing fan performance; examine duct system for possible improvements,

• stage fans that are in parallel configurations,

• commission the system thoroughly,

• optimize static pressure setpoint and implement reset control, and

• possibly remove return air fans.

Energy-efficient and properly sized motors are also recommended along with careful control strategies. Installing a self-contained, thermally powered device to each diffuser can add greater control to VAV systems by controlling individual spaces, rather than entire zones, and eliminate the need for VAV boxes. Such a device also offers VAV-style capabilities to CAV systems.

VAV retrofit costs and paybacks can vary widely. Installation problems related to fan control, reduced supply air distribution, location of pressure sensors and their reliability, in addition to deficient design, can diminish a VAV retrofit's performance. Because VAV boxes are relatively expensive and one is required for each zone, it is generally not cost effective to partition the space into many zones. Careful zone designation -- according to occupancy, internal loads and solar gain -- will maximize efficiency, increase comfort and reduce reheat.

When reheat cannot be eliminated, consider these steps to minimize it: ensuring thermostat calibration; increasing supply air temperatures during the cooling season; and monitoring reheat year round and possibly employing reheat only during winter months. Where reheat is used primarily to control humidity, a desiccant wheel or a heat pipe might be considered.

Downsizing existing VAV fan systems is a relatively low-cost way to save energy when loads have been reduced or when the air distribution system was oversized to begin with. The following are means to downsize fans or airflow requirements:

• Reduce static pressure setpoint to meet actual temperature and airflow requirements.

• Rightsize motors and upgrade to energy-efficient models; install larger pulleys.


• Replace the existing fan pulley with a larger one; that will reduce the fan's power requirements by reducing its speed.

• Make sure the fan's speed corresponds to the load. Reducing a fan's speed by 20 percent reduces its energy consumption by approximately 50 percent.

There are several ways to determine if VAV fan systems are oversized. If a motor's measured amperage is 25 percent less than its nameplate rating, it is oversized. If a fan's inlet vanes or outlet dampers are closed more than 20 percent, it is oversized. If the static pressure reading is less than the static pressure setpoint when inlets or dampers are open and VAV boxes open 100 percent, as on a hot summer day, the system is oversized. Again, be sure to consider IAQ requirements when downsizing air handling systems.

Chillers and thermal storage

No one wants to replace a perfectly good chiller just because of the CFC phaseout. But once load-reducing efficiency upgrades have been completed, it may actually be profitable to replace an oversized chiller. That's especially true given rising prices and tightening supplies of CFC refrigerants.

Oversized units 10 years or older are good candidates for replacement. A high-efficiency chiller reduces energy costs throughout its lifetime; initial costs are reduced because the replacement chiller is smaller than the old one. Depending on the old unit's efficiency and load, a high-efficiency chiller's energy consumption can be.15 to.30 kW/ton less, decreasing energy consumption by as much as 85 percent if combined with downsizing.

An alternative to replacement is to retrofit chillers to accommodate a new refrigerant and to match reduced loads. That may involve orifice plate replacement, impeller replacement and possibly compressor replacement, depending on the chiller's specifics.

Retrofitting may entail gasket and seal replacement and motor rewinding. Depending on the refrigerant and the way the retrofit is performed, the chiller may lose either efficiency or capacity. To determine whether replacement or retrofit is a better option, consider both initial and life-cycle costs.

Retubing the condenser and evaporator yields sizable energy savings but whether it makes sense, given its high cost, depends on the condition of the chiller. Water-cooled condensers are generally more efficient than air-cooled units. Because condenser water flows through an open loop, it is susceptible to fouling. Scale build-up will inhibit heat transfer efficiency; maintenance is therefore required to keep the surfaces clean.

Absorption chillers are an alternative to centrifugal models. Absorption chillers cost up to $150 per ton more than vapor compression chillers like centrifugal units, but can be profitable in areas of high electrical demand charges or where steam or gas is available, depending on the local utility rate structures. Using a combination of the two chiller types can reduce electrical demand charges.

Thermal energy storage (TES) uses conventional chiller equipment to produce conditioned water or ice (or occasionally another phase-change material) in off-peak periods. Water is withdrawn from storage during the day or at peak hours and circulated through the cooling system.

TES systems can be incorporated into new and existing systems and can provide partial load leveling or full load shifting. TES helps decrease operating and maintenance costs; in some cases, a smaller chiller can be specified. Some systems provide lower supply air and water temperatures, so air and water flow requirements can be cut.

Water-side improvements

Fill material, size and fan configurations affect cooling tower efficiency. Cellular fill (aka film packing) increases efficiency over other fill types. Oversizing the tower to allow for closer approach to ambient wetbulb temperature can improve its efficiency. Generously sizing the tower and increasing its share of the chiller load can make economic sense because a cooling tower's initial cost and energy use per ton are less than a chiller's.

At part-load conditions, applying a VSD to the fan (or pump) will improve the tower's efficiency. Systems with VSDs and several fans are more efficient when all tower cells are operating at reduced speed as opposed to one or two cells at full speed.

Because cooling towers contain large heat exchange surfaces, fouling -- scale or slime build-up -- can be a problem. The efficiency of improperly treated systems can be improved with effective water treatment. High-efficiency towers are available; induced-draft types are more popular and efficient than forced-draft towers. Performance can also be improved by increasing cooling surface area.

In traditional pumping systems, flow is generally constant volume; a throttle valve reduces flow at part-load conditions, inhibiting efficiency.

Installing VSDs on secondary pumps in variable flow systems, rightsizing pumps and motors to meet load requirements, and upgrading single loop systems to primary/secondary loop configurations can increase the performance and reliability of pumping systems. In upgrading chilled water pumps, it is important to meet maximum and minimum flow rates through the chiller.

Other cooling options

Desiccants are dehumidification materials which can be integrated into HVAC systems to reduce cooling loads and increase chiller efficiency while improving indoor air quality and comfort. Formerly found only in niche and industrial applications, desiccant cooling is extending throughout commercial markets.

Desiccants make sense when the cost to regenerate them is low compared to the cost to dehumidify below dewpoint and can reduce HVAC energy and peak demand by more than 50 percent in some cases.

Evaporative coolers provide one of the most economical and efficient means of cooling, using up to 75 percent less energy than vapor-compression systems. Though initial cost is typically higher, paybacks for evaporative coolers range between six months and five years. Though evaporative coolers are particularly prevalent in the arid West and Southwest, they can service most U.S. climates. E-Source states that, in combination with evaporative cooling, desiccant cooling can eliminate refrigerative air conditioning in many climates.

Hybrid systems that integrate evaporative cooling with conventional HVAC technologies offer additional opportunities. To improve performance consider lower air velocity; better fill materials; higher fan, pump and motor efficiencies, including VSDs; better belts or direct drive; improved housing; improved controls; and duct sealing. Proper maintenance is key to energy-efficiency.

Packaged air-conditioning units are typically found in buildings or building zones where the cooling load is less than 75 tons. Running these units at part load can severely reduce efficiency. They are generally not as efficient as chiller systems but can be upgraded and rightsized when replaced. Existing systems can be improved by using higher efficiency compressors, larger condensers and evaporators, and VSDs, though life expectancies of 10 to 12 years for these technologies may mean that retrofits are not cost-effective.

Heat pumps are among the most energy-efficient heating and cooling technologies available today. Low operating costs, increased reliability and long life expectancies improve their viability. They function best in moderate climates and proper sizing is critical.

Multi-unit configurations can service larger loads and provide zoning; large, modernized central units offering capacities of up to 1000 horsepower or 750 kilowatts are gaining popularity. Air-to-air type heat pumps are the most common because of low up-front costs; ground supply heat pumps are the most efficient but tend to have higher initial costs.

Boiler upgrades

Especially in colder climates, improved boiler performance -- with improved fuel and airflow controls over a range of load conditions and increased heat transfer surface areas -- can contribute substantially to energy savings. Smaller units arranged in modular systems increase efficiency up to 85 percent while small units replacing those with open-loop condensing systems shoot combustion efficiency up to 95 percent.

Boiler retrofits, combined with improved maintenance measures, can also increase efficiency -- up to 90 percent. New burners, baffle inserts, combustion controls, warm-weather controls, economizers, blowdown heat recovery and condensate return conversions provide increased efficiency opportunities. A smaller "summer" boiler might be a good option when a boiler is required year round though at reduced capacities in warmer conditions. The much smaller summer boiler is sized for reduced loads; the main boiler is shut down.

HVAC upgrades can provide tremendous economic benefits, improve occupant comfort and system reliability, and reduce operating costs. But to maximize benefits and minimize capital investment, load-reducing measures, such as lighting upgrades, should precede HVAC system upgrades.