When Facility Executives Need HVAC Upgrades

You want to include a major HVAC renovation in the plan for this year. How do you convince an owner to complete a retrofit that the building needs? You need to demonstrate, first, how the upgrade will improve the building and, second, how this increases the value of the building for the owner.


Some managers may think it is simple to convince an owner to spend thousands of dollars on an upgrade. They assume that an owner will want to complete a project so the building remains state-of-the-art. However, most owners — institutions, for example — view the building as an asset similar to stocks or bonds. They need to see the value of the property increase as a result of their cash outlay.


A second reason commonly given by managers to owners is that the office building will operate more efficiently after the retrofit, thus reducing utility costs. However, tenants usually pay their share of the building’s operating costs based on the amount of space they occupy.


Therefore, the tenants, not the owner, will benefit from the reduced utility costs. The owner pays for the renovation at the time the work is done. The cost of the work is then amortized and passed through to the tenants over the lifetime or payback of the project. The owner will spend the money today and only recoup it over time while the tenants will experience the immediate benefit.


This is the challenge faced by a fictional facility manager we’ll call John Philips, who is responsible for the hypothetical Spencer Building. Built 10 years ago, The Spencer Building is a class A office building in a downtown market. Like many buildings in the marketplace, the 240,000 rentable square foot building is 100 percent occupied with no major leases rolling over for seven to 10 years. Philips is aware that the owner’s objective is to hold this building for at least two to five more years. Although only 10 years old, the building’s HVAC system has two problems. First, the energy management system is not state-of-the-art and does not provide the building with efficient operation and sufficient control. Second, the parts of the mechanical equipment are expensive to maintain.



Philips has recommended upgrading the EMS system and installing variable frequency drives (VFV) on major equipment motors. The upgrade of the EMS system will include new power supplies, bases, transducers, wiring and associated relays. The existing temperature sensors will be replaced and new direct digital controllers will be installed for the interior and exterior air handling units, 24 in all. Static pressure controllers, solar load sensors and control relays will also be added to the EMS, giving the operating engineers more control points to ensure tenant comfort levels and increased monitoring capability. All of the new sensors and relays will be linked by a networking cable in a user-friendly package to a desktop computer with a Pentium microprocessor, graphics card, high-speed modem, color monitor and color printer.


VFDs will be installed on all motors and pumps. VFDs provide a staged start-up of equipment, preventing “spikes,” or sharp increases in electric demand. Motor speed can also be controlled by a VFD to operate more efficiently when equipment is at part load. Other advantages to VFDs are increased equipment life, decreased maintenance costs and automatic restart of equipment after power failures.



The system upgrade was bid to five companies with the recommended vendor bidding on this work for $326,978. The vendor has also given the option of a lease of this system at $422,100 at 11 percent for 60 months. This cost includes energy accounting, bill auditing and benchmarking reports for the first year.


The economic analysis that follows is based on the upgrade package just described; however, a similar approach can be taken with any HVAC system upgrade.


Owner’s Plans

Because the building may be for sale in the next two to five years, Philips knows the owners will want an increase in value at time of sale and a quick return on investment. To prove the increase in value, Philips will rely on the income-capitalization method of appraisal. The income-capitalization method is based on the net operating income (NOI) — the result of subtracting the operating expenses from rents received. If rents go up or expenses go down, NOI increases; higher NOI means higher value.


What’s more, an HVAC retrofit may make a building more appealing to tenants than other buildings in the area, thus increasing rents. Further, a retrofit project usually decreases utility costs.


The income-capitalization method divides the income by a cap rate, defined by market conditions, to find value. Based on the NOI for the building and a cap rate of 9 percent, the current value of The Spencer Building is $50,666,666.



At the Spencer Building, occupancy is already 100 percent with no major leases expiring until the year 2015. Therefore, the upgrade will not attract new tenants so no increases in rent as a result of the project are expected.


However, if the building had vacant space and was located in a competitive market, it might have an edge in leasing over buildings with higher utility costs. A tenant pays operating expenses over a base year. A base year may be set at $10 per square foot. The tenant pays all operating expenses in excess of $10 per square foot; the owner bears the cost up to that amount. If the operating costs are $14 per square foot, the tenant is paying $4 per square foot. If the retrofit reduces costs by $0.50 per square foot, the tenants’ costs fall to $3.50 per square foot. The owner’s costs are not reduced. The benefit to the owner is that the tenant may be happy with the reduced costs and be more inclined to renew the lease.


Cutting Costs

The retrofit at the Spencer Building will reduce costs in several ways. The EMS will improve staging of equipment during start-up and shutdown schedules and increase detail of temperature sensing and automatic adjustment. The VFDs will reduce utility costs by operating at only the speed required to satisfy the comfort load; the current system provides constant volume and constant speed flow. Based on a review of the equipment and historical electrical data, energy savings are estimated at:




  • EMS base system utility savings: $96,154

  • VFD installation utility savings: $40,872

  • Total estimated annual utility savings: $137,026

  • Savings per square foot: $2.570


The system costs $326,978. As outlined above, the annual utility savings are $137,026, creating a payback period of 2.39 years. Annual utility savings will increase NOI by $137,026. This, in turn, produces an increase in value based on the income-cap method of $1,522,511. The new value of the building is $52,189,177.


Range of Benefits

Philips can present this project to the owner by citing the benefits of the upgrade. The physical improvements include:




  • Improved system control through installation of state-of-the-art equipment

  • Cost savings due to VFDs and improved response to temperature

  • Ease of operation by use of “point and click” methods

  • Reduction of engineering staff time required to program the system and to check concerns through the system rather than a physical site inspection

  • Reduced maintenance cost


More important are these financial benefits:




  • A payback period of less than 2.5 years

  • An increase in value in excess of $1.5 million dollars

  • Lower operating expenses for tenants


To win approval for capital projects, a facility manager must have two things: knowledge of the owner’s objectives and the ability to prove the improvements meet those goals. After this upgrade, the Spencer Building will have a state-of-the-art HVAC system and be worth more than before the renovation. This combination will make the building more attractive to potential purchasers. Based on the numerous benefits, the owner would probably approve this upgrade at the Spencer Building.

Thursday, November 3, 2011

20 New Honeywell Smart Variable Frequency Drives from DtiCorp.com

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 20 brand new Honeywell Smart Variable Frequency Drives. SmartVFD continues to provide great energy savings, and smart features such as, start-up wizards, graphic interface, built-in Fieldbus communications, PC software wizards, two PID loops, 5% DC choke, standard EMC/RFI filter, similar to other frame sizes in the SmartVFD product family.  The Honeywell SmartVFD HVAC and BYPASS are designed specifically for commercial buildings to deliver the energy savings that building owners and facility managers need. The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. SmartVFD is also designed to run 3 phase standard and high efficiency induction motors by varying the output voltage and frequency. The SmartVFD is easy to install, communicates effectively with building control systems to minimize energy consumption. The SmartVFD BYPASS is easy to specify, select, install and commission. It is the perfect complement to the advanced capabilities of the SmartVFD HVAC. The SmartVFD BYPASS configurations make it easy to select the right bypass to complete your drive package. All configuration are available in NEMA 1, NEMA 12 and ventilated NEMA 3R.




Features:



- Start-up Wizards—All you have to do is tell the VFD whether you have a pump or a fan, enter nominal motor information, and you are up and running.



- Graphic Interface—The easy-to-use keypad and interface deliver menu-driven programming and monitoring for fast, uniform commissioning. It’s also easy for the building owner or manager to learn and use, helping to reduce service calls. Plus, a manual is built into the keypad for easy access when needed.


- Built-in Communications—With BACnet®, N2 and Modbus built in, your customers will enjoy a lower total installed cost and reliable communications with the building management system.


- PC Software Wizards—Commissioning, programming and troubleshooting are all a snap thanks to these guided Startup and PID wizards.


- Built-in PLC—Another reason why SmartVFD HVAC is a great value for your customer, the built-in PLC eliminates the need for an expensive external controller.


- DC Choke for harmonic protection.


- Standard RIF Filter—Ensures that EMC/RFI requirements are met.


- Bypass Options—Meets specifications and system critical applications with a comprehensive bypass offering.


- Real-Time Clock—Battery included.


- Fire Mode for safe operation.


- Motor Switch Ride-Through–easy, fault-free maintenance.




Product Specifications:


- 5% DC Choke for harmonic protection.


- Standard RFI Filter—Ensures that EMC/RFI requirements are met.


- Fire Mode for safe operation.


- Enclosure classes NEMA 1, NEMA 12 or NEMA 3R


- Bypass Options—Meet specifications and system critical applications with a comprehensive bypass offering.


- Motor Switch Ride-Through—Easy, fault-free maintenance.



- Overvoltage trip and undervoltage trip protection


- Ground fault protection


- Mains and motor phase supervisions


- Overcurrent and unit overtemperature protection


- Motor overload, motor stall and motor underload protection


- Short-circuit protection of +24V and +10V reference voltage


- 6-pulse IGBT, PWM technology


- Intelligent cooling arrangement. Control and power airflow separated.


- Real-Time Clock—Battery included



- 98% Displacement Power Factor Rating


- 98.5% Efficiency at full load


- 0-320Hz output frequency capabilities


- 100KA SCCR (Short Circuit Current Requirement) compliant


- EMC harmonics: EN 61000-3-12 compliant.


- EMC radio frequencies: EN 61800-3 Category C2 built in. Complies with radiated and conducted emissions.


- RoHS compliant, no electrolytic capacitors, no lead in the circuit boards.


- Compliance: American Recovery and Reinvestment Act (ARRA)




 


Models available: HVFDSD3A0500G100, HVFDSD3A0500G200, HVFDSD3A0600G100, HVFDSD3A0600G200, HVFDSD3A0750G100, HVFDSD3A0750G200, HVFDSD3A1000G100, HVFDSD3A1000G200, HVFDSD3A1250G100, HVFDSD3A1250G200, HVFDSD3C1000G100, HVFDSD3C1000G200, HVFDSD3C1250G100, HVFDSD3C1250G200, HVFDSD3C1500G100, HVFDSD3C1500G200, HVFDSD3C2000G100, HVFDSD3C2000G200, HVFDSD3C2500G100, HVFDSD3C2500G200


 



About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.




Julian Arhire

Manager DtiCorp.com

Phone: 954.298.2515

Fax: 954.206.0767

Web: http://www.DtiCorp.com


 


###

Monday, April 11, 2011

12 New Honeywell NXL Drives/Bypass Assemblies From DtiCorp.com

Fort Lauderdale, FL – Popular Honeywell online retailer DtiCorp.com (http://www.DtiCorp.com) is introducing 12 brand new Honeywell NXL Drives/Bypass Assemblies. Honeywell Variable Frequency Drives (VFD) accept a control input and then output tailored PWM control signal to operate (motors, fans, pumps, etc.) with maximum efficiency. The VFD can be field-programmed without any extra devices or computer connections.


The NX Series, comprised of the NXL, NXS and NXP drive families, is a dual-microprocessor base Pulse Width Modulated (PWM) adjustable frequency AC drive. The NX Series drives offer a suite of simple to highly sophisticated and complex application packages for general HVAC and advanced water solutions. Built-in input and output EMI/RFI filters and input AC chokes provide compact, reliable drive protection and reduced interference to the surrounding environment. Advanced IGBT PWM modulating control delivers leading edge precision and system response.


NXL, NXS and NXP drives, ranging from 1 to 800 HP, offer a simple, low cost but sophisticated interface (NXL) or a multifeatured, alpha-numeric based keypad display (NXS, NXP). The both options are based on a common parameter set platform which offers maximum operator flexibility, maneuverability and control with the minimum possible complexity. Either through a straight-forward code structure (NXL) or in plain English (NXS, NXP), the operator is able to start-up or reset parameters in minutes. Both interface (keypad) systems offer “start-up wizards” for simpler applications requiring the minimum of parameter settings. Up to three monitoring values can be viewed simultaneously in all applications. The menu structure allows rapid movement throughout the parameter sets which include: basic; input; output; drive; prohibit frequency; motor control; protections; and auto-restart. Unique in the industry, the NX Series drive can easily be operated via a local PC for up/downloaded applications, standard and custom parameter sets (NCLoad) and monitored/controlled via a “no cost” advanced NCDrive interface application. Groups of parameter sets can be viewed simultaneously and changed as needed, active and fault history can be evaluated, a Service Info file can easily be produced for a time-stamped record of the current drive parameters, faults as well as hardware and software profile information. In addition, up to eight drive or motor parameters can be viewed “real time” and trending information saved via a snap-shot function. All NX Series drives include a suite of ready to use “out of the box” applications including: basic; standard; local/remote; multi-step; PID; multi-purpose; multiple fan or pump. Additional specialized industrial as well as advanced HVAC pump water solution applications can be downloaded to drives via NCLoad.



Features:


- Seven configurable applications built in.


- Easy commissioning through software or control panel.


- Devices can be wall-mounted or panel-mounted.


- Eleven protective functions (see Form 63-2600, Users Manual, Technical Data sections).


- Insulated gate bi-polar transistor (IGBT) technology.


- Modbus, BacNet, Device Net, Profibus, LobBus, NS available as options cards.


Specifications:


- Wire Type and Size is Model and Application Dependant.



- Power Supply:


- 208-240 Vac, 45-66 Hz, +10%, -15%.


- 380-500 Vac, 45-66 Hz, +10%, -15%.


- 525-690 Vac, 45-66 Hz, +10%, -15%.


- Operating Temperature: 14°F to 104°F (-10°C to 40°C).

- Storage Temperature: -40°F to 140°F (-40°C to 60°C).


- Humidity Range: 5 to 95% RH (non-condensing).


- Control Inputs:


- Voltage (Analog): 0-10 Vdc, 200k ohm differential.



- Resolution: 0.1%, ±1% accuracy.


- Current (Analog): 4-20 mA, 250 ohm differential.

- Digital: up to six, 24 Vdc, positive or negative logic.


- Control Output:


- Reference Voltage: 10V, +3%; maximum load 10 mA.


- Auxiliary Voltage: 24V, ±15%; maximum 250 mA.


- Current (Analog): 0-20 mA, 500 ohm maximum.

- Resolution: 10 bit.


- Accuracy: ±2%.



- Relay: Two programmable changeover relay outputs.


- Switching Capacity: 24 Vdc, 8A; 250 Vac, 8A; 125 Vdc, 0.4A.


- Digital: Open collector output, 50 mA, 48V.

- Switching Frequency Range:


- Up to and including 40 HP: 1 to 16 KHz (default: 10 kHz).


- 50 HP and higher: 1 to 10 KHz (default: 3.6 kHz).


- Approvals (Model Dependant):


- NEMA1.


- NEMA12.


- Underwriters Laboratories, Inc. (UL)


- Canadian Underwriters Laboratories, Inc. (CUL).


- CE.


- Mount vertically on a wall or other flat surface using four screws or bolts sized for the particular unit.


Models Available: NXBJ0015DL100F0000, NXBJ0020DL100F0000, NXBJ0030DL100F0000, NXBJ0040DL100F0000, NXBJ0050DL100F0000, NXBJ0075DL100F0000, NXBJ0100DL100F0000, NXBJ0150DL100F0000, NXBJ0200DL100F0000, NXBJ0250DL100F0000, NXBJ0300DL100F0000, NXBJ0400DL100F0000.


About Us: DtiCorp.Com (http://www.DtiCorp.com) carries more than 35,000 HVAC products, including industrial, commercial and residential parts and equipment from Honeywell, Johnson Contols, Robertshaw, Jandy, Grundfos, Armstrong and more. Our online catalog is easy to navigate and search, and all products have a picture and a description. If a customer has any questions about a product, they can call 800-757-5999 and speak with one of our product experts. Our mission is to offer the best prices anywhere to our customers.